Omron GRT1 - 11-2007 Operation Manual page 287

Slice i/o units
Table of Contents

Advertisement

GRT1-CP1-L Positioning Unit
Input A
Input B
266
The user can set the configuration tag to any value between 0 and 255. The
configuration tag is downloaded with the rest of the parameter settings to the
Counter Unit and uploaded with the rest of the parameter settings from the
Counter Unit.
■ Counter Input Mode
Select one of the following counter input modes.
Counter input mode
Phase differential ×1
Phase differential ×2
Phase differential ×4
Pulse and direction
Up/down Counter
Phase Differential Counting
The following figure illustrates the operation of phase differential counting.
×1
0
1
2
×2
0
1
2
3
4
×4
0
1
2
3
4
5
6
7
8
Description
Phase-shifted pulses are received on inputs A and B.
• When the pulses on input A lead the pulses on input B, the
counter value is incremented on the falling edge of input A.
• When the pulses on input B lead the pulses on input A, the
counter value is decremented on the rising edge of input A.
Phase-shifted pulses are received on inputs A and B.
• When the pulses on input A lead the pulses on input B, the
counter value is incremented.
• When the pulses on input B lead the pulses on input A, the
counter value is decremented.
• The counter value is changed on the rising and falling edges
of input A.
Phase-shifted pulses are received on inputs A and B.
• When the pulses on input A lead the pulses on input B, the
counter value is incremented.
• When the pulses on input B lead the pulses on input A, the
counter value is decremented.
• The counter value is changed on the rising and falling edge
of both input A and input B.
Input A pulses are counted and input B determines the direc-
tion of counting.
• While input B is OFF, the counter value is incremented.
• While input B is ON, the counter value is decremented.
• The counter value is changed on the falling edge of input A.
• The counter value is incremented when pulses are received
on input A.
• The counter value is decremented when pulses are received
on input B.
• The counter value is changed on the falling edge of input A
or B.
3
2
5
6
5
4
3
9
1011
12
1110
9
8
7
6
Section 7-5
1
2
1
2
3
5
4
3
2
1
2
3
4
5
2
4
6
7
8