Commands - Omron E5ZE-8 Communications Manual

Multipoint temperature controller
Table of Contents

Advertisement

Commands

2-1

Commands

Operational Status and Commands
Unit
@
MB: Memory bank
Basic Commands for Temperature Control
Command
Set Point
Write
Read
Process Value
Read
Output Value
Read
Proportional Band
Write
Read
Integral Time
Write
Read
72
The following provides a list of commands that can be used with the E5ZE.
If the following are designated when sending a command, a set of data can be
written or read.
Memory bank no. and control point no.: A
Data code:
Refer to 2-2 Writing Sets of Data and 2-3 Reading Sets of Data for details.
Header
MB
Control
code
point
OK: Valid
NO: Invalid
Header
Memory
code
bank
WS
0 to 7
A
RS
0 to 7
A
RX
0
RO
0
WB
0 to 7
A
RB
0 to 7
A
WN
0 to 7
A
RN
0 to 7
A
Data code
Control
Data code
point
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
0 to 7
00
A
00
0 to 7
00
01
AA
(see note)
A
00
01
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
AA
Data
FCS
Operation status
Operation
Operating
stopped
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
Section 2-1
*
s
Auto-
tuning
NO
OK
OK
OK
NO
OK
NO
OK

Advertisement

Table of Contents
loading

Table of Contents