Relationship Between Operating Status And Operating Commands; Set Values In Memory Banks - Omron E5ZE-8 Communications Manual

Multipoint temperature controller
Table of Contents

Advertisement

DeviceNet Explicit Messages Set Values and Measurement
4-4-4
Relationship between Operating Status and Operating
Commands
E5ZE status
Temperature control
Manual operation
Operation stop
Remote I/O
Temperature Control
Start/Stop Bit status
4-4-5

Set Values in Memory Banks

28
5. When the Initializing Setting Data command is executed, the parameters
in the storage area will be reset to the factory - set default values even if the
E5ZE is in RAM write mode.
6. Set the Temperature Control Start/Stop Bit for the applicable control point
to 1 before starting manual operation. (Refer to the graph in the next sec-
tion.)
The relationship between operating commands from the remote I/O Tempera-
ture Control Start/Stop Bit and operating commands from DeviceNet explicit
messages or the RS - 232C auxiliary setting jack is represented in the following
graph. Remote I/O data is refreshed every 200 ms. Operating commands that
are different from the status of the remote I/O Temperature Control Start/Stop
Bit will, therefore, be momentarily effective and will then immediately change
to the commands from the remote I/O.
®
®
Bit 0
1
Bit 1
0
Manual Operation Start
Command executed
Manual Operation Start
Command executed
The following variable type table shows the information required to monitor or
change the settings for the control points in memory banks 0 to 7.
®
Bit 0
1
Bit 1
Temperature Control
Start Command
executed
Manual Operation Start
Command executed
Section 4-4
®
0
Temperature Control
Start Command
executed