Writing Sets of Data

Control Operation Start and Stop
Command
Operation
Start
Stop
Manual Operation
Start
2-2

Writing Sets of Data

Function
Commands
Unit
@
00 to 0F
Unit
@
00 to 0F
78
OK: Valid
NO: Invalid
Header
Memory
code
bank
OS
0
OP
0
OM
0
Status Read (RX) can be used with a data code to read a variety of data as
shown in the following table.
Header
code
RX
A single command block can enable all the memory banks or control points to
share the same data or set the contents of all the data codes used by the
E5ZE.
Use the following command format so that all the memory banks can share
the same data and data code.
A is designated
Header
Control
A
point
code
0 to 7
or A
Use the following command format so that all the control points share the
same data and data code.
A is designated
Header
Bank
A
code
0 to 7
or A
Control
Data code
point
0 to 7
00
A
00
0 to 7
00
A
00
0 to 7
00
A
00
Memory
Control
bank
point
0
0 to 7 or A
Data code
Setting data
00 to nn
Data code
Setting data
00 to nn
Operation status
Operation
Operating
stopped
OK
OK
OK
OK
OK
OK
Data code
Data to be read
00
Process value
01
Output value
02
Status
03
Heater current value
04
Present set point
AA
The contents of data codes 00
to 02 in sequence
BB
The contents of data codes 00
to 04 in sequence
FCS
4 or 5 digits
FCS
4 or 5 digits
Section 2-2
Auto-
tuning
NO
OK
NO
*
s
Terminator
*
s
Terminator