Connecting External I/O

2-4

Connecting External I/O

2-4-1 Output Connection Examples

30
This section provides motor driver connection examples. When actually con-
necting a motor driver, be sure to first check the specifications of the motor driver
to be used.
Pulses are not output when the output transistor in the pulse output section is
OFF. (For direction output, OFF indicates CCW.)
Do not use a 24-VDC power supply for pulse output in common with the power
supply for other I/O.
ON
Output transistor
OFF
CW/CCW Pulse Outputs
CW
CCW
Pulse and Direction Outputs
Pulses
Direction
During pulse output
CW
CW
Output transistor ON
Section
2-4
CCW
CCW
Output transistor OFF