Reference Information

This section provides reference information on the DXP HD 4K PLUS Series. The following topics are discussed:

Mounting the Switcher

Downloading Updated Firmware
Network Setup
Mounting the Switcher
The DXP HD 4K PLUS series switchers can be placed on a table top (with the four provided rubber feet attached
to the bottom) or mounted to a rack.

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the DXP HD 4K PLUS
switcher in a rack.
CAUTION:
Elevated operating ambient temperature — If the equipment is installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room
ambient temperature. Therefore, install the equipment in an environment compatible with the maximum
ambient temperature (TMA = +122°F, +50°C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe
operation of the equipment is not compromised.
Mechanical loading — When mounting the equipment in the rack, ensure that uneven mechanical
loading does not cause a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit, consider the effect that
circuit overloading might have on overcurrent protection and supply wiring. Consider equipment
nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay
particular attention to supply connections other than direct connections to the branch circuit (for
example, use of power strips).