Extron electronics DXP HD 4K PLUS User Manual page 103

4k hdmi switchers
Table of Contents

Advertisement

Command
IP Control Port Commands (continued)
Passwords
NOTES:
• The factory configured passwords for all accounts on this device have been set to the device serial number. If the
unit is reset to factory settings, these passwords are set to no password.
• Passwords are case-sensitive.
• The pipe (
|
) character is invalid for passwords.
• A password cannot be a single space.
Set administrator password
Clear administrator password
View administrator password
Set user password
Clear user password
View user password
KEY:
X4@
= Password
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
E X4@
}
CA
Ipa•
E
}
Ipa•
•CA
E
}
CA
****
E X4@
}
CU
Ipu•
E
}
Ipu•
•CU
E
}
CU
****
Length can be 0 to 128 characters. All human-readable characters are
permitted except
space.
DXP HD 4K PLUS Series • SIS Configuration and Control
X4@]
]
]
]
or
X4@]
]
]
]
or
|
. Passwords are case-sensitive and cannot be a single
Additional Description
Set the administrator password.
Reset or clear the administrator
password.
View the administrator password.
If there is a valid password, the
]
response is ****
. If there is
no password, the response is
]
.
Set the user password.
Reset or clear the user
password.
View the user password. If there
is a valid password, the response
]
is ****
. If there is no
password, the response is
]
.
95