Reference
Information
This section provides procedures for mounting the DTP T USW 333 switching transmitter
and disconnecting the ground between it and a compatible receiver.

Mounting the Switcher

ATTENTION:
The 1-inch high, half rack width DTP T USW 333 switching transmitter can be placed on a
table, mounted in a rack, or mounted under a desk or table.

Tabletop Use

Affix the included rubber feet to the bottom of the unit and place it in any convenient
location.

Mounting kits

Mount the unit using any optional compatible mounting kit listed at www.extron.com, in
accordance with the directions included with the kit. For rack mounting, see
Mounting Guidelines
Mounting the Switcher
Disconnecting the Ground
Installation and service must be performed by authorized personnel only.
Avoid ground potential differences between the switching transmitter and receiver
installation sites, which can lead to equipment damage or a missing or unstable
picture. If a potential difference cannot be avoided, remove the ground connection
between the units and locally power both units (see Disconnecting the Ground on
page 32).
L'installation et l'entretien doivent être effectués par le personnel autorisé
uniquement.
Évitez les différences de potentiel de mise à la terre entre les sites d'installation
de commutation émetteur récepteur, qui pourraient endommager l'équipement
ou rendre l'image invisible ou instable. Si une différence de potentiel ne peut être
évitée, enlevez la connexion de mise à la terre entre les unités et alimentez les deux
unités localement (voir Disconnecting the Ground à la terre page 32). .
on the next page.
DTP T USW 333 • Reference Information
UL Rack-
31