Command
EDID Commands
NOTE: See
EDID Minder
View EDID in Hex
View EDID native resolution
Import EDID
Export EDID
KEY:
X!
= Input number
X5)
= EDID record
X5!
= EDID resolution and rate
X5@
= EDID slot
X5#
= EDID filename
ASCII Command
(Host to Switcher)
on page 3 for information on available EDID.
E
X!
}
R
EDID
E
X!
}
N
EDID
E
X5@
X5#
}
I
,
EDID
E
X5@
X5#
}
E
,
EDID
1 through
maximum number of outputs
<
256 bytes of binary data in Hex
Native resolution and refresh rate from current EDID input assignment,
translated from Hex
DXP 42 PLUS — 01-04 = input slot, manually populated via PCS
DXP 44 PLUS — 01-04 = input slot,
05-08 = automatically populated with sink EDID from the output.
DXP 84 PLUS — 01-08 = input slot, 09-12 = automatically populated with
sink EDID from the output.
DXP 88 PLUS — 01-08 = input slot, 09-16 = automatically populated with
sink EDID from the output.
DXP 168 PLUS — 01-16 = input slot, 17-24 = automatically populated
with sink EDID from the output.
DXP 1616 PLUS — 01-16 = input slot, 17-32 = automatically populated
with sink EDID from the output.
NOTE: See
lists of the available EDID.
EDID file name and path (can be a full path name). EDID file format is
carrying 128 or 256 bytes of binary data.
Response
(Switcher to Host)
X5)]
X5)]
EdidR
X5!]
X5!]
EdidN
X5@]
EdidI
X5@]
EdidE
EDID tables for DXP HD 4K PLUS
DXP HD 4K PLUS Series • SIS Configuration and Control
Additional Description
X5)
View the EDID
X!
input slot
.
Verbose modes 2 and 3
View the EDID native resolution
X5!
and refresh
from input slot
Verbose modes 2 and 3
X5@
Import EDID table
X5#
.
X5@
Export EDID table
>
starting on page 4 for
in Hex from
X!
.
from file
X5#
to file
.
.bin