IBM XStation 130 Set Up And Operation Manual page 64

Table of Contents

Advertisement

Configuration Error Codes
Error Code
Configuration Change
Action
RA
161,169
Display
Check for damaged or un- 1
plugged display cables.
162
Non-volatile RAM checksum
Press F1 to recalculate check- 1
sum.
163,167,168
World Trade ROM
1
164
Video memory/Display
Go to "Diagnostics" and test the 1
processor memory
display port.
165
Optional adapter (Token Ring, Go to "Diagnostics" and test the 1
Dual Async, or Disk Drive)
adapter and disk drive.
170
Mouse
Go to "Diagnostics" and test the 1
mouse.
Find the non-eonfiguration error code in the following table and take the indicated action. If
the problem persists, record all of the information that identifies the problem and refer to
"Recommended Action (RA)"on page 3-7.
Non-Configuration Error Codes
Error Code
Possible Areas of Failure
RA
None
All appears normal.
-
10x, 11 x
Detected system board error.
1
20x
System board memory error.
1
30x
Keyboard, keyboard cable, or system board error.
1
1101-2
System serial port or serial port fan out cable error.
1
1103-4
Dual Async adapter error.
1
2401 xxxx
Video memory error (xxxx
=
socket location).
1
2402 xxxx
Display processor memory SIMM error (xxxx
=
socket).
1
2405-6
Display processor error.
1
2407 xxxx
Invalid display processor SIMM found (xxxx
=
socket).
1
2408
No display processor SIMMs found.
1
24xx
Any other display processor error.
1
66xx
See LAN error analysis (Token-Ring) on page 3-5.
1
t - - -
77xx
See LAN error analysis (SLIP).
1
800x
Tablet error (x identifies the serial port 1-4).
1
860x
Mouse or system board error.
1
88xx
See LAN error analysis (Ethernet) on page 3-5.
-
-
10499
Disk drive requires format.
3
104xx xxxx
Disk drive error.
1
Any other code
Undetermined error.
1
Note:
The xxxx shows that an extended error code number may be present.
3-4
Setup and Operator Guide

Advertisement

Table of Contents
loading

Table of Contents