NOTE: The MX2010 systems configured for three-phase wye AC input power must use only
three-phase wye AC PDMs and AC PSMs. Systems configured for three-phase delta AC input
power must use three-phase delta AC PDMs and AC PSMs. AC and DC PSMs or PDMs must
not be mixed within a single system.
Table 8: MX2010 AC Power Supply Module LEDs
Label
Color
PWR OK
Green
Yellow
INP0
Green
Yellow
INP1
Green
Yellow
9. Repeat Steps
1
through
State
Description
On
Power is functioning normally with no alarms.
On
PSM controller is functioning normally.
Off
PSM is not functioning normally or the AC input voltage is out of
range.
On
AC input is within the required voltage range and the DIP switch is
set to on.
On
AC input is out of the required voltage range.
Off
AC input to the PSM is not present.
On
AC input is within the required voltage range and the DIP switch is
set to on.
On
AC input is out of the required voltage range.
Off
AC input to the PSM is not present.
8
for installing PSMs in slots 0, 1, and 2, where required.