Packaging List; Introduction; Approved Vent Components; Codes And Standard - Superior Fireplaces DRC3000-B Series Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRC3000-B Series Direct-Vent Gas Fireplaces
PACKAGING
All models include
The assembled vented gas fireplace heater is packaged with:

INTRODUCTION

These vented gas fireplace heaters are sealed combustion, air-circulating gas fireplaces designed for residential and
commercial applications.
Electronic fireplaces are designed with an electronic intermittent pilot ignition system. External electrical power is
required to operate these units. In the event of a power outage, four (4) AA batteries (in battery holder) provide
backup power for fireplace operation (excluding the blower).
NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc. It is imperative that control compartment, burners, and
circulating air passageways of the fireplace be kept clean.
NOTE: Diagrams and illustrations are not necessarily shown to scale.

APPROVED VENT COMPONENTS

These fireplaces are designed, tested, and listed for operation and installation with the following vent components
only:
Use only the correct size venting (4-1/2" inner and 7-1/2" outer).
These approved vent system components are labeled for identification. DO NOT use any other manufacturer's vent
components with these fireplaces.
CODES AND STANDARDS
These fireplaces comply with National Safety Standards and are tested and listed by PFS TECO (Report No. F13-094)
to ANSI Z21.88•-2019 (in Canada, CSA-2.33•-2019), and CSA-2.17-2017 in both USA and Canada, as vented gas
fireplace heaters.
These fireplaces are listed for installation in bedrooms and manufactured homes.
The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CAN/CSA C22.1.
8
Literature Kit (bag in bottom compartment containing Installation and Operation Instructions (this manual), Hot
Glass Safety Flyer, and Safety-In-Operation Warning Labels)
U-Shaped Vent Restrictor
15 feet of Two Conductor Wire
1 Non-Combustible Board, 2 Side Brackets and 1 Center Bracket
1 Header Shield
Reflective Black Glass Media (5 lb bag provided). No more than 3 lbs should be used in a 35" unit, 4 lbs in a 40"
unit or 5 lbs in a 45" unit.
Standard Hood
Front Ramp (for use with optional Firebox Liner Kits)
Remarqué : L'installation et la réparation devrait être confiées à un technicien qualifié. L'appareil devrait
faire l'objet d'une inspection par un technicien professionnel avant d'être utilisé et au moins une fois
l'an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera
produisent une quantité importante de pous-sière. Il est essentiel que les compartiments abritant les
commandes, les brûleurs et les conduits de circulation d'air de l'appareil soient tenus propres.
Secure Vent
Direct-Vent System Components,
®
Secure Flex
Flexible Vent Components, and
®
Z-FLEX
Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster Canada
®
Limited.
General Information
901191-00C, 07/2023