This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRC3000-B Series Direct-Vent Gas Fireplaces
Models
C
US
Report No. F13-094
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRC3035DEN-B
DRC3040DEN-B
DRC3045DEN-B
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces DRC3000-B Series

  • Page 1 Installation and Operation Instructions DRC3000-B Series Direct-Vent Gas Fireplaces P/N 901191-00 REV. C 07/2023 Models DRC3035DEN-B Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900911-02 DRC3040DEN-B Report No. F13-094 DRC3045DEN-B P901191-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 35” / 40” / 45” THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en...
  • Page 6: Appliance Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (bag in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Btu Input

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 BTU INPUT Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 35” Models 20,000 15,000 18,000 15,000 40”...
  • Page 10: Orifice Sizes-Sea Level To High Altitude

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 ORIFICE SIZES—SEA LEVEL TO HIGH ALTITUDE These fireplaces are tested and approved for installation at elevations of 0 - 4500 ft (0 - 1372 m) above sea level using the standard burner orifice sizes (Table 5).
  • Page 11: Cold Climate Insulation

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your fireplace with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which fireplace rests, if floor is above ground level.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in (Figure 5, Page 16). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 5, Page 16).
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 6” minimum side wall clearance, Mantel Depth Top View of a combustible wall 16 (407) Fireplace can project to any length.
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 18 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 10 - Fireplace Framing Specifications Models Framing NOTE: Dimension “D” is the construction to be 10-1/2 required framing depth when 35-7/8 36-1/4 38-3/4 18-1/2 23-3/8 2 x 4, or larger.
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 7A).
  • Page 20: Determine Vent Setup In The Combination Venting Unit

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with round outer flue covers and inner flue cover plates installed that will require removal before connecting the vent pipe.
  • Page 21: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Rough in the Electrical Supply, if Needed As necessary, rough in the fireplace electrical supply per NEC and local codes. Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2”...
  • Page 22: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. U-Shaped Vent 2. If necessary, assemble the vent restrictor and wing as detailed in Figure 13C.
  • Page 23: Connecting The Vent Pipe

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Connecting the Vent Pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive ® twist lock connections (Figures 14 - 15). All of the fireplaces covered in this document are fitted with collars having locking inclined channels.
  • Page 24 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Vent Section Length Table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter.
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, • 1” (26 mm) from all sides attic, ceiling insulation, etc.). For all vertical runs: NOTE: Attic insulation shield (H3907, see Page 55) must be •...
  • Page 26 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required. See Effective Vent Length (Pages 23 - 24) for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 7. Change vent direction of horizontal/inclined run. Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows (Page 23) for more information.
  • Page 28 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/ inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 29 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 18 - Rear Vent—Three Elbows Table 17 - Top Vent—Two 90° Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex , use ® ceiling firestop/ Ceiling firestop/ spacer SF4.5VF.
  • Page 30 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting with the most restrictive requirements as outlined in these instructions, local codes, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 6. Install the firestop/spacer at the ceiling. When using Secure Vent , use SV4.5VF firestop/spacer at ceiling joists; when ® using Secure Flex , use SF4.5VF firestop/spacer. If there is living space above the ceiling level, the firestop/ spacer must ®...
  • Page 32 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Figure 24 - Installing the Horizontal Termination Installing the Horizontal Termination, SV4.5HT-2 To help minimize water infiltration Firestop/Spacer (SV4.5HF) shown Typical (all models) or SV4.5HTSS (35” models only) it is recommended that the Fire- Termination on the exterior side of the wall.
  • Page 33 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum Feet Meters Feet Meters 1.524 0.305 3.048 0.610 4.572 0.914 When using Secure Flex, use Firestop/Spacer 7.62...
  • Page 35 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Feet Meters Feet Meters Feet Meters Wall firestop/spacer 1.524 0.610 0.305 Wall Firestop/Spacer SV4.5HF ** SV4.5HF**...
  • Page 36 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required.
  • Page 37: Compete The Field Wiring

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 F. Install three (3) sheet metal screws 120° apart through the flexible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection.
  • Page 38 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Electronic Wiring One of the following optional controls must be used: • ON/OFF Wall Switch • Thermostat, or • Remote Control See the Operation section on Page 58 for more details.
  • Page 39: Connect The Gas Line

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Figure 29 - Wiring Diagram—Junction Box 4. Connect the black power supply wire to the lower outlet’s black and red pigtail lead (Figures 28 and 29). Connect the white power supply wire to the...
  • Page 40: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Access the Control Compartment See Page 60 for instructions on Accessing the Control Compartment. Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications).
  • Page 41: Install The Firebox Liners

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Installing the Firebox Liners 1. If accessory panels are desired, the metal front ramp must be changed prior to installation. See Page 42. If accessory logs are desired, the rear panel must be removed to uncover the log positioning tabs prior to installation of the panels.
  • Page 42 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 INSTALLATION INSTRUCTIONS After removing Barrier and/or Facade and Glass Door per the fireplace user manual instructions, install the rear panel centered and flush to the firebox rear panel (see Figure 35A).
  • Page 43: Install The Accessory Logs, Rock Kits, And Glass Media

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 WARNING • Turn OFF all gas and electricity to the appliance before installing the embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 44 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 1. If necessary, remove the glass door per instructions (Page 48) 2. If installing Accessory Panels in this fireplace, the front ramp (see Figures 34 - 35) must be changed out prior to installation of these logs.
  • Page 45 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 5. Place log #2 using tabs #2 and #3 (Figure 39). Log #2 Figure 39* 6. Place log #4 as shown below (Figure 40). Log #4 Figure 40...
  • Page 46 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 7. Place log #5 using pin in log #4 and resting on the front metal ramp (Figure 41). Log #5 Figure 41 8. Place log #3 using pins on log #1 and log #2. Place log #6 as seen below making sure not to block any burner ports (Figure 42).
  • Page 47: Install The Glass Doors

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Installing the Glass Media 1. Place glass media in area between rear panel and front ramp as seen in Figure 43B below. Do not mound glass media. No more than 3 lbs of glass media should be used in a 35” unit, 4 lbs of glass media in a 40” unit or 5 lbs of glass media in a 45”...
  • Page 48 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 WARNING Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance. AVERTISSEMENT Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
  • Page 49 Figure 45 - Barrier NOTICE: All DRC3000-B series fireplaces require a 35” Barrier - Cat. No. F1839 barrier to reduce the risk of burns from the hot viewing 40”...
  • Page 50: 18. Adjust The Air Shutter To Ensure Proper Flame Appearance

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 18. Adjust the Air Shutter to Ensure Proper Flame Appearance Flame Appearance and Sooting The flame should be blue at the base, and yellow-orange in the body of the flame.
  • Page 51: Install The Hood

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Figure 47 - Burner Flame Appearance 35” / 40” / 45” Install the Hood after Fireplace is Cool NOTE: All models must have a hood installed prior to operation.
  • Page 52: 21. Blower Installation/Replacement

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 BARRIER INSTALLATION Installation (see Figures 47A and 47B) 1. Slide barrier into upper trim panel. NOTE: This panel will rotate for ease of installation. Figure 47A - Slide Barrier into Upper Trim Panel...
  • Page 53: 22. Install The Finishing Materials

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 3. Remove burner (one screw) and pilot. 4. Remove pan that is inset into floor being careful not to damage gasket. 5. Blower access is now possible. 6. Once complete, reassemble unit using the reverse of the steps above.
  • Page 54 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 55: 24. Installation Accessories

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 24. INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 56 Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 INSTALLATION ACCESSORIES (continued) Cat. No. Model Description Cat. No. Model Description Vertical Termination for flex (flat to 6/12) with flex adaptor, section 77L78 SV4.5F Roof Flashing - Flat 56L74...
  • Page 57: 25. Gas Conversion Kits

    Innovative Hearth Products Installation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 25. GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 58: Operation

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns.
  • Page 59 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN...
  • Page 60: Burn-In Period

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 61: Installing The Backup Batteries

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Installing the Backup Batteries With a battery backup, electronic fireplaces can automatically switch to battery power. In the event of a power outage, this allows ON/OFF operation (without blower functionality). Install new batteries before every burn season.
  • Page 62: Maintenance

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 MAINTENANCE Refer to the Maintenance Schedule (Page 64) for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 63 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Inspecting the Glass Gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the Control Compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 64 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and...
  • Page 65: Accessory Components

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 ACCESSORY COMPONENTS Glass Media Kits PORCELAIN PANELS Cat. Models Description H8412 CRSHGL-RBLKW Reflective Black H8424 CRSHGL-RBLU Reflective Blue H8413 CRSHGL-P Platinum Forced Air Kits One glass media kit (5 lb bag) of reflective black is provided.
  • Page 66 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 ACCESSORY COMPONENTS (continued) Cost Effective Solution Unit-Mountable Rocker Switch Kit • Simple On/Off operation This rocker switch kit can be installed directly • Works with millivolt and low voltage electronic...
  • Page 67: Lighting Instructions

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 LIGHTING INSTRUCTIONS, ELECTRONIC - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 68 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 LIGHTING INSTRUCTIONS, ELECTRONIC - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 69: Troubleshooting

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 TROUBLESHOOTING ELECTRONIC SYSTEMS Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 70: Technical Service

    Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns a. When contacting your dealer please have your model and serial numbers of your fireplace ready.
  • Page 71 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 REPLACEMENT PARTS Cat. No. Models Description F4814 DRC3035DEN-B 35” DV Cont Dual EL NG F4815 DRC3040DEN-B 40” DV Cont Dual EL NG F4816 DRC3045DEN-B 45” DV Cont Dual EL NG This list contains replaceable parts used in your firebox.
  • Page 72 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 REPLACEMENT PARTS (continued) Electronic This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on Page 70 of this manual.
  • Page 73 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 74 Innovative Hearth Products Operation DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 75: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 76 Innovative Hearth Products Installation and Operation Instructions DRC3000-B Series Direct-Vent Gas Fireplaces 901191-00C, 07/2023 Superior.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name...