Quick Links

P/N 900787-04 REV. G 06/2020
A French manual is available upon request. Order
P/N 900787-05.
Ce manuel d'installation est disponible en francais, s
implement en faire la demande. Numéro de la pièce
900787-05.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
DRI2000TEN Series
C
US
Report # F17-137
INSTALLATION AND OPERATION
MODELS
DRI2027TEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900787-04
DRI2032TEN

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces DRI2000TEN Series

  • Page 1 INSTALLATION AND OPERATION Direct-Vent DRI2000TEN Series P/N 900787-04 REV. G 06/2020 P900787-04 A French manual is available upon request. Order P/N 900787-05. MODELS Report # F17-137 Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 900787-05.
  • Page 2 SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and must be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable Fireplace Insert chimenea All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    CONGRATULATIONS! Preparation For Flex Liner Installation ....... 15 Vertical Venting ..........16 Zero Clearance Fireplace Installation ......16 When you purchased your new gas fireplace insert, you joined Flue Restrictor ............ 16 the ranks of thousands of individuals whose answer to their home Firebox Liner (standard) ........
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARN- APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD INGS LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- Votre foyer a été livré avec des étiquettes de sécurité qui Su chimenea incluye etiquetas de instrucciones de tion labels that are to be affixed to the operation and doivent être collées à...
  • Page 7: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD WARNINGS...
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     C AUTION: Hot while in operation. Do not touch. Severe Burns IMPORTANT SAFETY AND WARNING may result. Keep children, clothing furniture, gasoline and other INFORMATION liquids having flammable vapors away. ATTENTION: L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures graves. Sur- ...
  • Page 10: Orifice Size/Altitude Adjustment

    IMPORTANT: When installing these appliances into a factory ORIFICE SIZE/ALTITUDE ADJUSTMENT built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice (i.e.
  • Page 11: Codes And Approvals

    COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS WARNING / AVERTISSEMENT These appliances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for •...
  • Page 12: Pre-Installation

    Packaging List PRE-INSTALLATION Insert Body Packaging List Features 1 Insert Body Installation Options 1 Power Cord Manufactured (Mobile) Home 1 Log Set Natural Gas Or Propane (LP) 1 Bag of Embers Bedrooms 1 Literature Package (installation and operation manual, warning labels, and hardware kit*).
  • Page 13: Insert And Fireplace Dimensions

    O.D. = 2-15/16" (75mm) 3" (77mm) Top View 3" (77mm) Right Side View Front View Left Side View Model 17-7/8" 14-7/8" 10-7/8" 26-5/8" 16-3/4" 8-3/4" 14-3/8" 20-3/4” DRI2027 (454mm) (378mm) (276mm) (676mm) (425mm) (222mm) (365mm) (527mm) 19-3/8” 15-7/8” 11-7/8” 31-5/8” 21”...
  • Page 14: Clearances To Combustibles

    CLEARANCES TO COMBUSTIBLES Insert Leveling At each front and rear corner of the insert is an adjustable leg provided Minimum Clearances to Combustibles to level the insert should the hearth of the fireplace be uneven. To adjust the legs, use a 1/4" wrench. Minimum clearances include any projections such as shelves, window sills, mantels, spacers/standoffs or surfaces to combustible construction etc.
  • Page 15: Installation

    INSTALLATION The existing fireplace chimneys may take various contours which Venting Installation the flexible liners will accommo- Vertical Cap date. However, keep the flexible Your IHP appliance must be vented to the outside in accordance with the liner VERTICAL and avoid bend- current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, ing.
  • Page 16: Vertical Venting

    Vertical Venting (see Figure 5, Page 15) Flue Restrictor The flue restrictor settings shown in Figure 7 are for typical installations The vent pipes must be connected to the proper collars on the unit and and are based upon laboratory testing. To achieve proper combustion, the exhaust vent pipe must be connected to the termination cap or the unit adjustments may be needed to account for variables in the installation, will not operate.
  • Page 17: Firebox Liner (Standard)

    Firebox Liner Kit 1. Remove the glass door following the instructions provided in this manual (Page 27). 2. Place the rear liner panel against the back of the Firebox and resting on the burner support tray. 3. One at a time, install the side liner panels by sliding them into place (Figure 8).
  • Page 18 NOTE: If applicable, install the firebox liner before placing the stone. Logs can be installed after the volcanic stone. Installing the volcanic stone, and glowing embers: If necessary, remove the glass door (Page 27). 2. Spread the decorative volcanic stone in a pleasing pattern on the firebox floor to the front and sides of the burner (Figure 10).
  • Page 19 DRI2027 and DRI2032 Log Installation Instructions - Position the left front log (2) on the left front log tab and the left burner locating tab (See Figures 14A/B and 16). The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs.
  • Page 20: Gas Line Installation

    Gas Line Installation The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of After leveling, position the insert in the fireplace - holding it about six the gas supply piping system at test pressures equal to or less than inches out from its final location.
  • Page 21: Air Shutter Adjustment

    Air Shutter Adjustment Battery Backup - Battery Installation This appliance has an air shutter control lever located behind the Full This appliance is equipped with a battery backup system. It requires Front Facade, under the glass door (see Figure 20). The lever is linked four (4) "AA"...
  • Page 22: Operating Instructions

    Room Air Circulation Blower OPERATION Plug in the three-prong power cord into the provided J-Box/Receptacle (see Figure 22). Do not cut or remove the grounding prong from the Pre-Lighting Checklist power cord. Be sure to check these items before the initial lighting of the insert: The blower ON/OFF-Speed control switch is located on the left side Full Front Facade.
  • Page 23: Flame Color And Behavior

    OPERATION Burner Flame Appearance Optional Remote Control or Wall Switch Soot above Soot at See instructions provided with your optional control kit. No Soot at Flame Tip Flame Tip Flame Tip Dark Orange Semi-Transparent Initializing The System For The First Time Flame Ports on Pan Yellow Flame...
  • Page 24: Wiring Diagram

    Ecoflow Pilot Assembly Main Burner Thermocouple Ground - Connector to Chassis Ground or Valve Body Thermocouple - To "S" Terminal on Main Module (Not Polarity Learn (black) Sensitive) IPI/ Cont Pilot (yellow) Dry - 7.5VDC Contact Hi/Lo (blue) 1-Amp Switches Adaptor Burner On/Off (brown) Battery Pack...
  • Page 25: Maintenance And Servicing

    MAINTENANCE AND SERVICING Igniter Ignitor Igniter Pilot Pilot Hood Hood Pilot Hood WARNING Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Thermocouple Sensor Thermocouple CAUTION: Wear gloves and safety glasses for protection while doing required maintenance.
  • Page 26: Door Removal

    Glass Door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. See Detail A SEE DETAIL A • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 27: Glass Maintenance

    Glass Door Cleaning and Maintenance Cleaning: Do not remove or clean the glass door when hot. When cool, the glass may be cleaned with a clean, soft cloth and a household glass cleaner. For cleaning white condensation from the interior glass, use a gas fireplace glass cleaner available from your dealer.
  • Page 28: Replacing A Damaged Barrier

    Replacing A Damaged Barrier • If the barrier becomes damaged, the barrier shall be replaced Barrier with the manufacturer’s barrier for this appliance. • For model DRI2032, use with barrier part number J4785. For model DRI2027, use with barrier part number F4343. Follow installation instructions.
  • Page 29: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 30: Replacement Parts

    Contact an IHP dealer to obtain any of these parts. REPLACEMENT PARTS - DRI2027 Cat. No. Item # Description Item # Description Cat. No. ECOFLOW PARTS Firebox Door Assembly with Glass H9174 Pilot Assembly, Ecoflow, Natural Gas J7935 Gas Train Assembly, NG F3399 Pilot Assembly, Ecoflow, Liquid Propane J7962...
  • Page 31 REPLACEMENT PARTS - DRI2027 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 32 Contact an IHP dealer to obtain any of these parts. REPLACEMENT PARTS - DRI2032TEN Cat. No. Cat. No. Item # Description Item # Description ECOFLOW PARTS Firebox Door Assembly with Glass J7594 Gas Train Assembly, NG, 32" Insert F3126 Pilot Assembly, Ecoflow, Natural Gas J7935 Gas Train Assembly, LP, 32"...
  • Page 33 REPLACEMENT PARTS - DRI2032TEN NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 34: Accessories

    ACCESSORIES - DRI2027 Surround Kit* 46” (1168 mm) 23” Product Reference Information (584 mm) Shipping Cat. No. Description Ship. Weight Volume 12-1/8” DRI2027, Traditional, 27" (308 mm) F3407 87.5 lb. 12.22 cu. ft. Small Insert 41” Full Front Facade Kits (required accessory) * (1042 mm) 38”...
  • Page 35 ACCESSORIES - DRI2032TEN Surround Kit* 46” (1168 mm) 23” Product Reference Information (584 mm) Ship. Cat. No. Description Ship. Weight Volume 10-3/4” DRI2032TEN, Traditional, (273 mm) F3026 96 lbs 18.1 cu. ft. 32" Medium Insert Full Front Facade Kits (required accessory) * 38”...
  • Page 36: Insert Labels

    SAFETY / LISTING LABEL - DRI2027TEN SERIAL MODEL DRI2027TEN DRI2027 MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. F17-137 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
  • Page 37 SAFETY / LISTING LABEL - DRI2032TEN SERIAL DRI2032TEN MODEL DRI2032TEN MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Report No. 16-204 AUBURN, WA., USA 98001 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 &...
  • Page 38 LIGHTING LABEL - DRI2000 Series FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which •...
  • Page 39: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 40: Product Reference Information

    PRODUCT REFERENCE INFORMATION 1. The model number of the appliance. 2. The serial number of the appliance. 3. The part number. We recommend that you record the following important information 4. The description of the part. about your appliance. Please contact your IHP dealer for any questions 5.