Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRC3000-B Series Direct-Vent Gas Fireplaces

Prepare the Fireplace Top Spacers

2.
1. The two (2) 4" standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the
detached end (Figure 7A).
2. Bend the standoffs as shown (Figure 7B).
3. Align the hole in the standoff with the hole in the fireplace top, and secure with the screw that was removed in
Step 1 (Figure 7B).
Figure 7A - Unassembled Standoff
Positioned Flat as Shipped From the Factory
Screw

Route the Gas Supply Line to the Fireplace

3.
1. Route a 1/2" (13 mm) gas line to the left side of the fireplace (Figure 8).
NOTE: Gas lines must be routed, assembled, and made of materials that are in strict accordance with local
codes and regulations. All fireplaces are factory-equipped with a flexible gas line connector and a 1/2" shutoff
valve (Figure 30, Page 39).
Figure 8 - Routing the Gas Line - 35", 40", 45" Models
(77 mm)
Proper Sizing of Gas Line
Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed
per requirements outlined in the National Fuel Gas Code, NFPA 54—latest edition (USA) or CAN/CGA-B149.1—latest
edition (Canada).
The gas supply line should not be connected to the appliance until step 13. Connect the Gas Line (Page 39).
NOTE:
All fireplaces are factory-equipped with a flexible gas line connector and 1/2" shutoff valve (Figure 30, Page 39).
See Massachusetts Horizontal Vent Requirements for additional requirements for installations in the state of
Massachusetts in the USA.
A pipe joint compound rated for gas should be used on the threaded joints. Ensure propane-resistant
compounds are used in propane applications. Be very careful that the pipe compound does not get inside the
pipe.
A sediment trap in the supply line as close as possible to the fireplace is recommended.
Check with the local building official for local code requirements (e.g., Are below grade penetrations of the
gas line allowed?, etc).
If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this
is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
This can result in insufficient fuel delivery that can cause sooting, delayed ignition, or other
malfunctions. Any damage resulting from an improper installation is not covered by the
limited warranty.
Top Standoff
Fireplace Front
Left side front corner of
fireplace framing
Pipe coupling
(recommended)
7-5/8"
(195 mm)
3"
Figure 7B - Assembled Standoffs
Top Standoff
Fireplace
Front
CAUTION
Installation
901191-00C, 07/2023
19