Superior Fireplaces DRC3000-B Series Installation And Operation Instruction Manual page 29

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRC3000-B Series Direct-Vent Gas Fireplaces
Table 17 - Top Vent—Two 90° Elbows
H
Ceiling firestop/
spacer SV4.5VF *
Wall firestop/
V1
spacer SV4.5HF **
*
When using Secure Flex
, use
®
ceiling firestop/spacer SF4.5VF.
**
When using Secure Flex, use
wall firestop/spacer SF4.5HF.
H Maximum
Feet
Meters
Feet
5
1.524
5
1.524
10
3.048
15
4.572
25
7.62
V + V
+ H = 60 ft (18.3 m) maximum
1
H = 25 ft (7.62 m) maximum
Install the U-shaped vent restrictor in any vent run
with more than 6 ft of vertical rise. See Page 23 for
more information.
If 25 ft of (H) horizontal vent run is needed,
then 5 ft (straight section) minimum of (V)
vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For
every 1 ft of (V) vertical, you are allowed 5
ft of (H) horizontal run, up to a maximum
horizontal run of 25 ft.
Minimum 6 ft and maximum of 60 ft of
vertical venting.
Table 18 - Rear Vent—Three Elbows
V1
V
V Minimum
H + H
Maximum
Meters
Ft
Elbow Only
5
1
0.305
10
2
0.610
15
3
0.914
20
5
1.524
H = 8 ft (2.4 m) maximum
H + H1 = 20 ft (6.1 m) maximum
V + V1 + H + H1 = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent run
with more than 6 ft of vertical rise. See Page 23 for
more information.
If 20 ft of (H) horizontal vent run is needed,
then 4 ft (straight section) minimum of (V)
vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For
every 1 ft of (V) vertical, you are allowed 5
ft of (H) horizontal run, up to a maximum
horizontal run of 20 ft.
NOTE: The vent system may have a
maximum of three (3) 90° elbows.
Minimum 6 ft of vertical venting.
*
When using
Secure Flex
ceiling firestop/
spacer SF4.5VF.
**
When using
Secure Flex, use
wall firestop/
spacer SF4.5HF.
H1
Ceiling
firestop/spacer
SV4.5VF *
Wall firestop/
spacer
SV4.5HF **
Ceiling
firestop/spacer
SV4.5VF *
V
V
H
H Maximum
V Minimum
1
M
Ft
M
Ft
1.524
2
0.610
1
3.048
4
1.219
2
4.572
6
1.829
3
6.096
8
2.438
4
Table 19 - Top Vent—Three Elbows
, use
®
Ceiling firestop/
spacer SV4.5VF
V1
*
H1
*
When using Secure Flex
ceiling firestop/spacer SF4.5VF.
**
When using Secure Flex, use
wall firestop/spacer SF4.5HF.
H + H
Maximum
1
Feet
Meters
M
5
1.524
0.305
5
1.524
0.610
10
3.048
0.914
15
4.572
1.219
20
6.096
H + H1 = 20 ft (6.1 m) maximum
V + V1 + H + H1 = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent
run with more than 6 ft of vertical rise. See Page
23 for more information.
If 20 ft of (H) horizontal vent run is
needed, then 4 ft (straight section)
minimum of (V) vertical vent will be
required.
This table shows a 1 (V) to 5 (H) ratio.
For every 1 ft of (V) vertical, you are
allowed 5 ft of (H) horizontal run, up to
a maximum horizontal run of 20 ft.
NOTE: The vent system may have a
maximum of three (3) 90° elbows.
Minimum 6 ft and maximum of 60 ft of
vertical venting.
Installation
901191-00C, 07/2023
Wall firestop/
spacer
SV4.5HF **
H
V
, use
®
V Minimum
Feet
Meters
Elbow Only
1
0.305
2
0.610
3
0.914
4
1.219
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drc3035den-bDrc3040den-bDrc3045den-b

Table of Contents