Verify Proper Fireplace Operation - Superior Fireplaces DRC3000-B Series Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRC3000-B Series Direct-Vent Gas Fireplaces
Access the Control Compartment
See Page 60 for instructions on Accessing the Control Compartment.
Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are
used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and
other openings can be caulked or stuffed with unfaced fiberglass insulation.
All codes require a shutoff valve mounted in the supply line. The orientation of the shutoff valve should face the
front. Figure 30, Page 39 illustrates two methods for connecting the gas supply. A sediment trap is recommended to
prevent moisture and debris in the gas line from damaging the valve.
Test Factory and Field Connections for Gas Leaks
Never use an open flame to check for leaks.
Turn on gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution.
NOTE: Using a soapy water solution is an effective leak test solution but it is not recommended, because the
soap residue that is left on the pipes/fittings can result in corrosion over time.
1. Light the fireplace (refer to the lighting instructions label in the control compartment or Pages 67-68).
2. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or
3. When the gas lines are tested and leak free, rinse off the leak testing solution

Verify Proper Fireplace Operation

14.
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions:
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of
air. When purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace
will not require purging. Inspect the pilot flame (carefully remove logs, if necessary).
Electronic Fireplace Inspection
To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
should engulf the thermocouple. Pilot should have two flames, one that engulfs the thermocouple and one that lights
the burner (see Figure 31).
Figure 31 - Electronic Pilot
Thermocouple
Thermocouple
40
gas odor is detected, turn the gas control knob (OFF/PILOT/ON) to the OFF position (millivolt units), or turn the
receiver or remote control to the OFF position (electronic units). Either tighten or refasten the leaking connection,
and then retest as described above.
Electronic Systems (Pages 67-68)
Igniter
Ignitor
Igniter
Pilot
Hood
Pilot Hood
Pilot Hood
Sensor
WARNING
Installation
901191-00C, 07/2023