Nortel SONET AccessNode Manual page 35

Site testing procedures
Hide thumbs Also See for SONET AccessNode:
Table of Contents

Advertisement

Procedure 2-2 (continued)
Measuring optical receiver performance
Step
18
Action
Remove the DS3 or STS-1 lockout by entering:
pr;dtlprot <type> ↵
lockout re <circuit pack group>↵
where
<type>
<circuit pack group> is the group with an asterisk in the lockout field
y ↵
A dot is displayed in the Lockout field.
If you used
a temporary DS3/STS mapper or
STS-1 interface card
test cords to set up a DS3 or
STS-1 daisy chain
—end—
AccessNode Site Testing Procedures 323-3001-221 Issue 2.0
DS3 tests, STS-1 tests, and optical in-bay tests 2-17
is ds3 or sts1
Then
leave the connection between the test
set and BNC I/O card in place for the
next procedure
remove the DS3 or STS-1 daisy chain

Advertisement

Table of Contents
loading

Table of Contents