4-4 Preparing for system integration
Procedure 4-1 (continued)
Enabling and disabling VTBM TIC VT 1.5 alarms
Action
Step
1
2
3
AccessNode Vol 3B 323-3001-221 Issue 2.0
Action
Display the TIC Facility screen for the STS-1. This screen requires alarms to
be provisioned:
fa tic <sts#>↵
where
<sts #>
is the number of the STS-1 facility: 1 or 2.
The TIC Facility screen is displayed for the selected STS-1.
Display the alarm provisioning screen:
almprov ↵
The TIC Fac Alarm Provisioning screen is displayed.
Set the STS-1 facility alarm points for on or off as required:
editstat <#> <status>↵
where
<#>
is the alarm point number. See Table 4-1 for a complete
list of alarms.
<status>
is the status of the alarm point: on or off. See Table 4-1
for defaults.
Table 4-1
STS-1 Facility Alarm Points
#
Alarm point
1
STS-1 Rx unequipped
2
STS-1 Rx RFI
3
STS-1 Rx path trace failure
4
STS-1 signal label mismatch
If you set an alarm point to off, the system prompts for confirmation.
Enter:
y ↵
The screen is updated with the new alarm point settings in reverse video.
Repeat step 3 for each alarm to be provisioned. When all the required alarms
are provisioned, continue with step 4.
—continued—
Default
on
on
on
on