Table of Contents

Advertisement

4-14 Preparing for system integration
Procedure 4-4 (continued)
Provisioning DS1s for an integrated configuration
Step
3
AccessNode Vol 3B 323-3001-221 Issue 2.0
Action
Change the parameters as required.
If you are provisioning
facility identifier
line coding
line build-out
frame format
alarm encoding
synchronization
performance monitoring
All newly provisioned values appear in reverse video as they are changed.
a. Provision the DS1 facility identifier by entering:
facid <identifier> ↵
where
<identifier>
Note: Lowercase characters are translated to uppercase. If you want the
facility ID to have mixed case characters or non-alphanumeric characters,
such as spaces, hyphens, or slash marks, begin the identifier string with a
single quotation mark (').
b. Provision the type of line coding by entering:
lcoding <type> ↵
where
<type>
c. Provision the line build-out range by entering:
lbo <range> ↵
where
<range>
—continued—
Then do
step a
step b
step c
step d
step e
step f
step g
is an alphanumeric string up to 38 characters
is the type of line coding:
b8zs (for GR-303 DMS or GR-303 MVI) or ami (for
TR-08)
is the line build-out range:
short (less than 46m)
medium (46m to 137m)
long (137m to 200m)