4-28 Preparing for system integration
Procedure 4-6 (continued)
Assigning new connections
Step
50
Assigning the DS1 as VLCM
51
52
53
54
55
56
57
58
AccessNode Vol 3B 323-3001-221 Issue 2.0
Action
If you now want to
make another assignment
exit from the tool
From the Manage Facility Assignments screen, you can change the End NE
A or End NE Z fields.
a. Tab to the End NE A field and display the Chooser menu by pressing
Ctrl_L / (or Keypad 3).
b. Select an available NE from the Chooser menu by pressing Space (or
Keypad 0).
c. Repeat the same procedure to change the End NE Z field.
The NE A Tributary and NE Z Tributary list appear.
Note the different assignments under the Assignment column.
Using the arrow keys move the cursor to an unassigned or assigned facility
you want to assign as VLCM.
Note: For DMS Access, the APC card must be NT4K52GB.
Select the List item menu using Ctrl_L (or Keypad 2).
The List item menu appears.
Using the arrow keys, move to the Assign as VLCM command, then press
Space (or Keypad 0).
The Assign as VLCM dialog appears.
In the System Number field, press Ctrl_L (or Keypad 3) to display the
chooser menu.
Use the arrow keys to move to the system number you want, then press
Space (or Keypad 0).
Tab to the Switch Port Number field, then press Ctrl_L (or Keypad 3) to
display the chooser menu.
The chooser menu appears.
Use the arrow keys to move to the switch port you want, then press Space
(or Keypad 0).
The switch port number appears in the Switch Port Number field.
Note: Ports 0 and 3 are reserved as signalling links. When you provision port
0 or 3, a dialog appears. The dialog allows you to assign a remote
maintenance module (RMM) channel to the signalling link so you can perform
line/loop testing.
—continued—
Then
return to step 12
go to step 60