Procedure 3-12 (continued)
Installing batteries
Battery options
Table 3-3
Table 3-3
Battery options
PEC
A0734525 Battery single block C&D FA-12-100
A0774151 Battery string hook up cable
A0773445 Battery single block East Penn
A0774150 Battery string hook up cable
A0773443 Battery single block Power Battery
A0774150 Battery string hook up cable
Note 1: One string must contain 4 single battery blocks.
Note 2: 672 lines provided: 4 strings are required. 864 lines provided: 5
strings are required. 1344 lines provided: 6 strings are required. 2016 lines
provided: 8 strings are required.
You can use your own external battery vault instead of the provided battery
compartment underneath the equipment compartment. The cabinet is equipped
in the AC compartment with knockout panels. To install battery cables through
the knockouts (see
vault").
Action
Step
1
lists the battery options
Description
12AVR100-3ET
CSL-12100
Procedure
Action
Install the batteries into the front and rear partitions of the battery
compartment (see
Figure
Note: The cabling color designation is RED = negative (-) and BLACK =
positive (+).
—continued—
3-13, "Installing battery cables from an external
3-24,
Figure
3-25, and
User Guide
Rel 1.0 Standard May 1999
Installation guidelines 3-39
Quantity
See Note 1 and 2
1 for each string
See Note 1 and 2
1 for each string
See Note 1 and 2
1 for each string
Figure
3-26).