Dante SETUP screen

On this screen, set and view the status of the built-in Dante
module and an SB-16D connected via the built-in Dante
module.
Tap Menu Screen > Rear Panel Setup > Dante Setup to open this
page.

Dante Settings page

1 MODULE status
This shows the status of the Dante module.
Item
Dante Device Name
Dante Module Staus
Software Version
Dante Firmware Version
Dante Model
4 - Mixer configuration and settings
Content
This shows the module name
of the Dante device.
This shows the status of the
Dante module.
This shows the version of the
built-in Dante module. This
is the same as the Product
Version shown in Dante
Controller.
This shows the firmware
version of the Dante system.
This is the same as the Dante
Firmware Version shown in
Dante Controller.
This shows the hardware type
of the built-in Dante module.
This is the same as the Dante
Model shown in Dante
Controller.
2 NETWORK status
This shows the status of the Dante network.
When in Redundant mode, settings will be shown for
the Primary connector on the left and for the Secondary
connector on the right.
When in Switched (daisy-chain) mode, only the left side will
be active.
Item
Content
This shows the selected connection mode.
Tap this area to open a window where
Switch
Redundant or Switched mode can be
selected. (default: Redundant)
This shows the IP address setting mode.
Tap this area to open a window where
Addressing
AUTO (DHCP) or STATIC can be selected.
(default: AUTO (DHCP))
If the Addressing item is set to "AUTO",
this will show the assigned IP address. If
it is set to "STATIC", this will show the IP
address set by the user.
IP Address
When the Addressing item is set to
"STATIC", tapping this area will open the
IP ADDRESS Screen. (See "IP Address/
Subnet Mask/Default Gateway setting
procedures" on page 108.)
If the Addressing item is set to "AUTO", this
will show the assigned subnet mask. If it
is set to "STATIC", this will show the subnet
mask set by the user.
Subnet mask
When the Addressing item is set to
"STATIC", tapping this area will open the
SUBNET MASK Screen. (See "IP Address/
Subnet Mask/Default Gateway setting
procedures" on page 108.)
This shows the Dante network link status.
LINK Status
This will be shown in red if it is not 1 G.
This shows the MAC address of the
MAC Address
Primary/Secondary Dante port.
NOTE
To confirm Dante network settings, the Dante module must
be restarted.
If Dante network settings have been changed, the APPLY
button will appear highlighted.
Tap the APPLY button when it is highlighted to open a
confirmation message.
Tap the REBOOT Dante button to restart the Dante module.