4 - Mixer configuration and settings
NOTE
If the SLOT1/SLOT2 button for the slot that has an IF-AE16
installed is tapped, a window will open that allows 8 pairs
of input signals to be selected for the master clock. Tap the
button for the input signal to set for the master clock.
A confirmation message will appear.
3.
Tap the OK button to switch the master clock.
NOTE
i If the SLOT 1 or SLOT 2 button is tapped when an IF-AN16/
OUT or IF-MTR32 is installed in that slot, or if no expansion
card has been installed in that slot, the following message
will appear and the master clock will not be selected.
36
TASCAM Sonicview 16XP/Sonicview 24XP V1.5.0
i If the selected external clock is unlocked, the unit will operate
using the internal clock. In this case the
the INT button as the clock in use, while
selected button for the unlocked source. The selected button
for the unlocked source will be highlighted red.
i When synchronization with the external master clock
becomes possible again, a message like the one below will
appear at the top of all touchscreens.
WORD clock regained. Can be re-synced to WORD.
Tap this message to open the SYNC CLOCK Screen on the
right touchscreen.
Tap the red-highlighted button with the
a confirmation message for switching back to the selected
master clock.
Tap the OK button to switch to synchronization with the
selected external clock.
ATTENTION
When switching the master clock, noise might occur in the
audio input and output.
Be aware of this when choosing when to change the master
clock.