2. Set the acceptable FRU for the slot:
hostname cli>
setfru slot fru_instance Acceptable_Fru_Types nonsun:picmg2.16
where fru_instance is the chassis slot number to be configured; valid values are 3 to
20. For example, if you want to set chassis slot 6 to allow a third-party node board,
enter the following:
hostname cli>
setfru slot 6 Acceptable_Fru_Types nonsun:picmg2.16
3. Insert the third-party node board into the configured slot.
4. Completely power off and on the system by locating the power switch at the rear
of the Netra CT 820 server; press it to the Off (O) position, then press it to the On
(|) position.
The slot is now configured to accept a third-party cPSB-only node board.
M
To Display FRU ID Information for a Third-
Party Node Board
1. Log in to the active distributed management card.
2. Enter the showfru command:
hostname cli>
where fru_instance is a chassis slot number from 3 to 20, and fru_field can be
Part_No (part number) or Serial_No (serial number). For example, to display
part number FRU ID information for a third-party node board in slot 6, enter the
following:
hostname cli>
For more information on FRU ID, refer to
Information" on page 12
page
68
Netra CT 820 Server System Administration Guide • March 2004
showfru slot fru_instance fru_field
showfru slot 6 Part_No
and
15.
"Specifying Netra CT Server FRU ID
"Displaying Netra CT Server FRU ID Information" on

Advertisement