Sun Microsystems Netra CT 820 Administration Manual page 77

Hide thumbs Also See for Netra CT 820:
Table of Contents

Advertisement

To Manually Recover a Board
M
1. Log in to the distributed management card.
2. Perform manual recovery operations on a board with the recoveryoperset
command:
hostname cli> pmsd recoveryoperset -s slot_num|all -o
where slot_num can be a slot number from 3 to 20, and all specifies all slots
containing node boards. For example, to instruct PMS to reboot slot 5 after a fault,
enter the following:
hostname cli> pmsd recoveryoperset -s 5 -o
To Automatically Recover a Board
M
1. Log in to the distributed management card.
2. Perform automatic recovery operations on a board with the recoveryoperset
command:
hostname cli> pmsd recoveryautooperset -s slot_num|all -o
pc|rst|rstpc|pd|rb|rbpc|none|trg [-d startup delay][-f on|off][-r retries][-n
inter_op_delay][-p reset_power-cycle_delay]
where slot_num can be a slot number from 3 to 20, and all specifies all slots
containing node boards. For example, to instruct PMS to automatically reboot slot
5 after a fault, with the default delays, retries, and failure power state, enter the
following:
hostname cli> pmsd recoveryautooperset -s 5 -o
Printing PMS Automatic Recovery Information
The pmsd recoveryautoinfoshow -s slot_num|all command can be used to
print information showing the configuration information affected by the
recoveryautooperset command.
rb
rb
Chapter 3 Administering Your System
pc|rst|rstpc|pd|rb
63

Advertisement

Table of Contents
loading

Table of Contents