Table 13: Troubleshoot AP Disconnection Issues
LED Color
(Continued)
Blink Pattern
Blinking yellow two times
Issue
The switch or AP is
experiencing a Layer 2
issue.
Steps to Troubleshoot
"uptime":
707675.367648
}
3. Check the firewall logs
to see whether any
policy is blocking the
https:/ /ep-
terminator.mistsys.net
/about
URL.
1. Run a cable test to
verify that the cable
connected to the AP is
working correctly.
2. Check whether the
switch port connected
to the AP learns the
MAC address of the
AP.
3. Check for any eth0
errors on the switch
port.
4. Change the cable and
switch port and verify
that the AP powers
on.
5. If you have a working
AP, swap it with the
faulty AP. Check
whether the issue
persists.
NOTE: If your APs are
already installed and
you cannot swap any
AP, skip this step.