The following table provides a guide for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the
highest priority must be installed first using the slot priority indicated. All other expansion cards must be installed in card priority and slot
priority order.
Table 16. Expansion card installation order
Card priority
Card type
1
RAID
2
10 Gb NICs
3
FC8 HBA
4
1 Gb NICs
5
Non-RAID
68
Installing and removing system components
Slot priority
PowerEdge RAID
Internal PERC slot
Controller (PERC)
H730 and H330
PERC H830 Full
2
Height
PERC H830 Low
1
Profile
Intel and Broadcom
2
Dual Port
Intel and Broadcom
1
Dual Port Low Profile
Qlogic QLE2562,
2
Qlogic QLE2560,
Emulex LPE12002,
Emulex LPE12000,
Emulex LPE15000,
and Emulex
LPE15002
Qlogic QLE2562,
1
Qlogic QLE2560,
Emulex LPE12002,
Emulex LPE12000,
Emulex LPE15000,
and Emulex
LPE15002 Low
Profile
Intel and Broadcom
2
Dual and Quad Port
Intel and Broadcom
1
Dual and Quad Port
Low Profile
12GB SAS HBA Full
2
Height
12GB SAS HBA Low
1
Profile
Maximum allowed
1
1
1
1
1
1
1
1
1
1
1