Field settings table
Breadcrumb Field code
Setting name
9.9.B
[5-0B]
Limit 3
9.9.C
[5-0C]
Limit 4
9.9.D
[4-01]
Priority heater
9.9.F
[7-07]
BBR16 activation (#)
└─ Energy metering
9.A.1
[D-08]
Electricity meter 1
9.A.2
[D-09]
Electricity meter 2
└─ Sensors
9.B.1
[C-08]
External sensor
9.B.2
[2-0B]
Ext. amb. sensor offset
9.B.3
[1-0A]
Averaging time
└─ Bivalent
9.C.1
[C-02]
Bivalent
9.C.2
[7-05]
Boiler efficiency
9.C.3
[C-03]
Temperature
9.C.4
[C-04]
Hysteresis
Installer settings
9.D
[C-09]
Alarm output
9.E
[3-00]
Auto restart
9.F
[E-08]
Power saving function
9.G
Disable protections
└─ Overview field settings
9.I
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
9.I
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
9.I
[0-02]
High ambient temp. for LWT add zone heating WD curve.
9.I
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
9.I
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
9.I
[0-05]
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
9.I
[0-06]
High ambient temp. for LWT add zone cooling WD curve.
9.I
[0-07]
Low ambient temp. for LWT add zone cooling WD curve.
9.I
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
9.I
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
9.I
[0-0D]
High ambient temp. for DHW WD curve.
9.I
[0-0E]
Low ambient temp. for DHW WD curve.
9.I
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
9.I
[1-01]
High ambient temp. for LWT main zone heating WD curve.
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Only applicable in Swedish language.
Range, step
Default value
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0: None
1: BSH
2: BUH
0: Disabled
1: Enabled
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0: No
1: Outdoor sensor
2: Room sensor
-5~5°C, step: 0,5°C
0°C
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
0: No
1: Bivalent
0: Very high
1: High
2: Medium
3: Low
4: Very low
-25~25°C, step: 1°C
0°C
2~10°C, step 1°C
3°C
0: Normally open
1: Normally closed
0: No
1: Yes
0: disabled
1: Enabled
0: No
1: Yes
[9-05]~min(45,[9-06])°C, step: 1°C
[2-0C]=0
25°C
[2-0C]=1
35°C
[2-0C]=2
35°C
[9-05]~[9-06]°C, step: 1°C
[2-0C]=0
35°C
[2-0C]=1
45°C
[2-0C]=2
65°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-15°C
[9-07]~[9-08]°C, step: 1°C
[2-0C]=0
18°C
[2-0C]=1
7°C
[2-0C]=2
18°C
[9-07]~[9-08]°C, step: 1°C
22°C
25~43°C, step: 1°C
35°C
10~25°C, step: 1°C
20°C
35~[6-0E]°C, step: 1°C
55°C
45~[6-0E]°C, step: 1°C
60°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-10°C
-40~5°C, step: 1°C
-15°C
10~25°C, step: 1°C
15°C
7/11
Installer setting at variance with
default value
Date
Official Value
4P586458-1 - 2019.07