Daikin EPRA16DAW1 Installer's Reference Manual page 109

Hide thumbs Also See for EPRA16DAW1:
Table of Contents

Advertisement

EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
Model (power supply)
*6V (6V: 1N~ 230 V)
*6V (6T1: 3~ 230 V)
*9W (3N~ 400 V)
8
|
Connections to backup heater power supply
2
4
K5M
1
3
SWB
X6M
1
3
F1B
I
I
2
4
Q1DI
1N~, 50 Hz
L
N
230 V AC
2
4
K5M
1
3
SWB
X6M
1
3
F1B
I
I
I
2
4
Q1DI
3~, 50 Hz
L1 L2 L3
230 V AC
2
4
K5M
1
3
SWB
X6M
1
3
F1B
I
I
2
4
Q1DI
3N~, 50 Hz
L1 L2 L3
400 V AC
Electrical installation
6
14
5
13
5
7
I
I
6
8
6
14
5
13
5
7
I
6
8
6
14
5
13
5
7
I
I
6
8
N
Installer reference guide