15.5 Wiring diagram: Indoor unit

See the internal wiring diagram supplied with the unit (on the inside of the indoor unit upper front panel). The
abbreviations used are listed below.
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
Notes to go through before starting the unit
English
Notes to go through before starting
the unit
X1M
X2M
X5M
X6M
X7M, X8M
1
Note 1: Connection point of the power
supply for the BUH/BSH should be
foreseen outside the unit.
Backup heater power supply
 6T1 (3~, 230 V, 6 kW)
 6V (1N~, 230 V, 6 kW)
 6WN/9WN (3N~, 400 V, 6/9 kW)
User installed options
 LAN adapter
 WLAN adapter
 Domestic hot water tank
 Remote user interface
 Ext. indoor thermistor
 Ext outdoor thermistor
 Digital I/O PCB
 Demand PCB
 Safety thermostat
Main LWT
15
|
Translation
Notes to go through before starting the
unit
Main terminal
Field wiring terminal for AC
Field wiring terminal for DC
Backup heater power supply terminal
Booster heater power supply terminal
Earth wiring
Field supply
Several wiring possibilities
Option
Not mounted in switch box
Wiring depending on model
PCB
Note 1: Connection point of the power
supply for the backup heater/booster
heater should be foreseen outside the
unit.
Backup heater power supply
 6T1 (3~, 230 V, 6 kW)
 6V (1N~, 230 V, 6 kW)
 6WN/9WN (3N~, 400 V, 6/9 kW)
User installed options
 LAN adapter
 WLAN adapter
 Domestic hot water tank
 Dedicated Human Comfort Interface
(BRC1HHDA used as room thermostat)
 External indoor thermistor
 External outdoor thermistor
 Digital I/O PCB
 Demand PCB
 Safety thermostat
Main leaving water temperature
Technical data
Installer reference guide