Installation site requirements of the outdoor unit..................55 6.1.2 Additional installation site requirements of the outdoor unit in cold climates..........58 6.1.3 Installation site requirements of the indoor unit ..................58 Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 3
To access the most used commands ......................117 Configuration wizard............................... 119 Possible screens ................................120 9.3.1 Possible screens: Overview ..........................120 9.3.2 Home screen..............................121 9.3.3 Main menu screen............................124 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 4
Solving problems based on error codes ......................... 224 13.4.1 To display the help text in case of a malfunction ..................224 13.4.2 Error codes: Overview ............................ 225 Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 5
Piping diagram: Indoor unit ............................234 15.4 Wiring diagram: Outdoor unit ............................235 15.5 Wiring diagram: Indoor unit ............................240 16 Glossary 17 Field settings table EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Indicates a situation that could result in death or serious injury. WARNING: FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. Only use accessories, optional equipment and spare parts made or approved by Daikin. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
▪ In places where there is a risk of fire due to the leakage of flammable gases (example: thinner or gasoline), carbon fibre, ignitable dust. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Use a vacuum pump to evacuate the installation. NOTICE After all the piping has been connected, make sure there is no gas leak. Use nitrogen to perform a gas leak detection. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
If applicable. See the installation manual or installer reference guide of your application for more information. WARNING The selection of the brine MUST be in accordance with the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
If NOT factory installed, a main switch or other means for disconnection, having a contact separation in all poles providing full disconnection under overvoltage category III condition, MUST be installed in the fixed wiring. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 12
Install power cables at least 1 m away from televisions or radios to prevent interference. Depending on the radio waves, a distance of 1 m may not be sufficient. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 13
Running the product in reversed phase can break the compressor and other parts. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Format: Paper (in the box of the indoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. The original documentation is written in English. All other languages are translations. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
About the documentation Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required).
Page 16
Note: There is also an installer settings table in the user reference guide. This table has to be filled in by the installer and handed over to the user. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit. Crane Keep the slings within the marked area to not damage the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 18
After unpacking, carry the unit using the slings attached to the unit. See also: ▪ "3.2.2 To unpack the outdoor unit" [ 19] ▪ "6.3.4 To install the outdoor unit" [ 65] ±150 4× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
About the box 3.2.2 To unpack the outdoor unit a, b Accessories EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Installation manual – Discharge grille NOTICE Unpacking – Front corners. When you remove the front packaging corners, hold the box containing the discharge grille to prevent it from falling. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Handles at the back of the unit Handles at the bottom of the unit. Carefully tilt the unit to the back so that the handles become visible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Location Model identification Example: EP R A 14 DA V3 Code Explanation European hydro-split outdoor pair heat pump High water temperature – ambient zone 2 (see operation range) Refrigerant R32 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Certain options might not be available in your country. 4.3.1 Possible combinations of indoor unit and outdoor unit Indoor unit Outdoor unit EPRA14 EPRA16 EPRA18 ETVH/X16 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
To enable the power saving consumption control by digital inputs you must install the demand PCB. For installation instructions, see the installation manual of the demand PCB and addendum book for optional equipment. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 25
Use the system in various Smart Grid applications. For installation instructions, see the installation manual of the LAN adapter and the addendum book for optional equipment. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 26
For installation instructions, see the installation and operation manual of the Human Comfort Interface (HCI) as room thermostat. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Setting up the domestic hot water tank ▪ Setting up the energy metering ▪ Setting up the power consumption control ▪ Setting up an external temperature sensor EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Emergency [9.5] to Automatic. NOTICE An overpressure bypass valve can be integrated in the system. Keep in mind that this valve might not be shown on the illustrations. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
For your daily needs, you can use preset values and schedules. To deviate from your daily needs, you can temporarily overrule the preset values and schedules, or use the holiday mode. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 30
Code: [C-05] heating or cooling demand. Benefits ▪ Wireless. The Daikin external room thermostat is available in a wireless version. ▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it is specifically designed for the heat pump system. ▪...
Page 31
Benefits ▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent cooling capacity. ▪ Efficiency. Optimal energy efficiency because of the interlink function. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 32
The shut-off valve Configuration Setting Value Unit temperature control: 1 (External room thermostat): Unit operation is decided by the ▪ #: [2.9] external thermostat. ▪ Code: [C-07] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Setup A Main leaving water temperature zone B Room 1 C Room 2 a Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 34
99] ▪ For each room, a shut-off valve (field supplied) is installed to avoid leaving water supply when there is no heating or cooling demand. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 35
▪ For more information about connecting the electrical wiring to the unit, see: "8.2 Connections to the outdoor unit" [ 92] "8.3 Connections to the indoor unit" [ 99] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 36
Combination: Underfloor heating + Heat pump convectors – Multiple rooms Setup A Main leaving water temperature zone B Room 1 C Room 2 a External room thermostat b Heat pump convectors (+ controllers) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Main zone = Zone with the lowest design temperature in heating, and the highest design temperature in cooling ▪ Additional zone = Zone with the highest design temperature in heating, and the lowest design temperature in cooling EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 38
▪ For more information about connecting the electrical wiring to the unit, see: "8.2 Connections to the outdoor unit" [ 92] "8.3 Connections to the indoor unit" [ 99] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 39
Set to follow the thermo demand of the main zone. Shut-off valve If the main zone must be shut off during cooling mode to prevent condensation on the floor, set it accordingly. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
During heating operation of the auxiliary boiler, the auxiliary boiler operates to achieve the desired water temperature set via the auxiliary boiler controller. Setup ▪ Integrate the auxiliary boiler as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 41
Make sure the auxiliary boiler and its integration in the system complies with applicable legislation. ▪ Daikin is NOT responsible for incorrect or unsafe situations in the auxiliary boiler system. ▪ Make sure the return water to the heat pump does NOT exceed 60°C. To do so: Set the desired water temperature via the auxiliary boiler controller to maximum 60°C.
Page 42
To prevent freeze-up of the water piping, the auxiliary gas boiler must have a fixed setpoint ≥55°C, or a weather-dependent setpoint ≥T (°C) –30 –25 –20 –15 –10 –5 (°C) Outdoor temperature Minimum weather-dependent setpoint for auxiliary gas boiler EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Example: If the DHW consumption of a family (4 persons) per day is as follows: ▪ 3 showers ▪ 1 bath ▪ 3 sink volumes Then the DHW consumption = (3×100 l)+(1×150 l)+(3×10 l)=480 l EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 44
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
For more information, see "9 Configuration" [ 116]. ▪ You can program a schedule to control the DHW pump via the user interface. For more information, see the user reference guide. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
You can read out the energy data: Per month Per year INFORMATION The calculated produced heat and consumed energy are an estimation, the accuracy cannot be guaranteed. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
5.5.3 Normal kWh rate power supply General rule One power meter that covers the entire system is sufficient. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 48
Indoor unit (L e Outdoor unit (L f Backup heater (L f Indoor unit (L g Booster heater (L g Backup heater (L h Booster heater (L EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Permanent power limitation is useful to assure a maximum power or current input of the system. In some countries, legislation limits the maximum power consumption for space heating and DHW production. Power input Time EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
5.6.2 Power limitation activated by digital inputs Power limitation is also useful in combination with an energy management system. The power or current of the entire Daikin system is limited dynamically by digital inputs (maximum four steps). Each power limitation level is set via the user interface by limiting one of the following: ▪...
(step 1). Then power consumption is limited as follows: Produced heat Consumed energy Consumed energy Outdoor unit Backup heater Limited outdoor unit operation EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
You can connect one external temperature sensor. It measures the indoor or outdoor ambient temperature. We recommend to use an external temperature sensor in the following cases: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 54
To protect the outdoor unit, the internal sensor of the outdoor unit is always used. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Mind the spacing guidelines. See "15.1 Service space: Outdoor unit" [ 232]. NOTICE ▪ Do NOT stack the units on each other. ▪ Do NOT hang the unit on a ceiling. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 56
This is to prevent corrosion caused by high levels of salt in the air, which might shorten the life of the unit. Install the outdoor unit away from direct sea winds. Example: Behind the building. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 57
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed only by authorised persons. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Heating only models + conversion kit (EKHVCONV2) ▪ Mind the measurement guidelines: Maximum height difference between indoor unit and outdoor 10 m unit Maximum total water piping length 50 m EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Precise water piping length can be determined using the Hydronic Piping Calculation tool. The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator.
3 Remove the transportation stays (2×), and dispose of them. 6.2.4 To close the outdoor unit NOTICE When closing the outdoor unit cover, make sure that the tightening torque does NOT exceed 4.1 N•m. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 62
▪ When you need access to the high voltage switch box 2× 5 If you need access to the high voltage components, remove the high voltage switch box cover. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 Tilt the switch box to the front and lift it out of its hinges. 2× 3 Place the switch box lower on the unit. Use the 2 hinges located lower on the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise. Fix the unit securely by means of foundation bolts in accordance with the foundation drawing. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Make sure not to cover the drain hole in the bottom plate of the unit. 6.3.4 To install the outdoor unit 1 Carry the unit by its slings, and put it onto the installation structure. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Install the unit on a base to make sure that there is proper drainage in order to avoid ice accumulation. ▪ Prepare a water drainage channel around the foundation to drain waste water away from the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 67
Drain hole O-ring (delivered as accessory) Drain plug (delivered as accessory) Hose (field supply) NOTICE O-ring. Make sure the O-ring is installed correctly to prevent leakage. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
4 Align and attach the left side. 5 Align and attach the middle part. 6 Align and attach the right side. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
68] ▪ "6.3.7 To remove the discharge grille, and put the grille in safety position" [ 69] 1 Remove the upper part of the discharge grille. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 70
4 Align the ball stud and hook on the grille with their counterparts on the unit. 5 Insert the hook. 6 Insert the ball stud. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor irregularities. The maximum allowed deviation is 1°. ≤1° EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
4 Reattach the side panel. Ensure the water can flow through the drain tube. It is recommended to use a tundish to collect the water. Option 1: Through the left side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 73
Unit installation Option 2: Through the right side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Closed circuit. Use the indoor unit ONLY in a closed water system. Using the system in an open water system will lead to excessive corrosion. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 75
Drainage – Pressure relief valve. Connect the drain hose properly to the drain to avoid water dripping out of the unit. See "6.4.4 To connect the drain hose to the drain" [ 72]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
7.1.3 To check the water volume and flow rate The indoor unit has an expansion vessel of 10 litre with a factory-set pre-pressure of 1 bar. To make sure that the unit operates properly: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 77
Use the following graph to determine the maximum water volume for the calculated pre-pressure. 200 220 Pre-pressure (bar) Maximum water volume (l) Water Water + glycol Example: Maximum water volume and expansion vessel pre-pressure EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 78
In case the minimum flow rate cannot be reached, a flow error 7H will be generated (no heating or operation). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Pg = (0.3+(H/10)) bar = (0.3+(0/10)) bar = 0.3 bar ▪ The corresponding maximum water volume at 0.3 bar is 290 l. (See the graph in "Maximum water volume" [ 77]). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
1 Connect the shut-off valve (with integrated filter) to the outdoor unit water inlet, using thread sealant. Water OUT (screw connection, male, 1") Water IN (screw connection, male, 1") EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 81
To avoid damage to the surroundings in case of water leakage, it is recommended to close the domestic cold water inlet shut‑off valves during periods of absence. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 Cut out the rubber grommet on top of the unit, and remove the stop. The recirculation connector is placed below the hole. 3 Route the recirculation piping through the grommet and connect it to the recirculation connector. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Glycol leaking out of the freeze protection valves. Freeze protection by glycol About freeze protection by glycol Adding glycol to the water lowers the freezing point of water. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 84
Add glycol according to the table below. Lowest expected outdoor Prevent from bursting Prevent from freezing temperature –5°C –10°C –15°C –20°C — –25°C — –30°C — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 85
Normally closed valves (recommended – field supply) Part Description An automatic air intake (for air supply) should be installed at the highest point. For example, an automatic air purge. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
For piping in free air, it is recommended to use the insulation thickness as shown in below table as a minimum (with λ=0.039 W/mK). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 87
The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator. This recommendation ensures good operation of the unit, however, local regulations may differ and shall be followed.
▪ Make electrical connections to the fixed wiring. ▪ All components procured on-site and all electrical construction MUST comply with the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Place the round crimp-style terminal on the wire up to the covered part and fasten the terminal with the appropriate tool. Stranded conductor wire Round crimp-style terminal ▪ Use the following methods for installing wires: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Preferential kWh rate power supply 1 Power supply for outdoor unit 2 Power supply and interconnection cable to indoor unit 3 Power supply for backup heater EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
3 Insert the cables at the back of the unit, and route them through the factory- mounted cable sleeves into the switch box. For the power supply, use the factory-mounted cable. a1+a2 Power supply cable (factory-mounted cable) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 93
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. Wires: (3+GND)×1.5 mm² EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 94
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 95
▪ Connect the wires to the terminal block. ▪ Fix the cable with a cable tie. Use the factory-mounted cable. Wires: 3N+GND Maximum running current: Refer to name plate on unit. — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 96
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. Wires: (3+GND)×1.5 mm² — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 97
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
8.2.2 To reposition the air thermistor on the outdoor unit This procedure is only necessary in areas with low ambient temperatures. Required accessory (delivered with the unit): Thermistor fixture. Click EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Maximum running current: 100 mA For the main zone: ▪ [2.9] Control ▪ [2.A] Thermostat type For the additional zone: ▪ [3.A] Thermostat type ▪ [3.9] (read-only) Control EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 100
▪ Installation manual of the remote indoor sensor ▪ Addendum book for optional equipment Wires: 2×0.75 mm² [9.B.1]=2 (External sensor = Room) [1.7] Room sensor offset EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 101
To allow for energy buffering in the domestic hot settings water tank, on the user interface, make sure to set [9.2.1]=4 (Domestic hot water = Integrated). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
In case of normal kWh rate power supply Interconnection cable Wires: (3+GND)×1.5 mm² (= main power supply) — 1 2 3 1 2 3 X11YB X11YA X11Y Interconnection cable (=main power supply) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 103
Interconnection cable (=main power supply) Normal kWh rate power supply Preferential power supply contact 3 Fix the cables with cable ties to the cable tie mountings. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
0.22 Ω 2 kW 3~ 230 V 5 A — 4 kW 3~ 230 V 10 A — 6 kW 3~ 230 V 15 A — 3 kW 3N~ 400 V 4 A — 6 kW 3N~ 400 V 9 A — 9 kW 3N~ 400 V 13 A — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 105
Connections to backup heater power supply *6V (6V: 1N~ 230 V) Q1DI 1N~, 50 Hz 230 V AC *6V (6T1: 3~ 230 V) Q1DI 3~, 50 Hz L1 L2 L3 230 V AC EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the valve control cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the electricity meters cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the domestic hot water pump cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. Wires connected to the alarm output Wire between X2M and A4P Installation of EKRP1HBAA is required. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the space cooling/heating ON/OFF output cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the power consumption digital inputs cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
2 User interface panel 3 Upper switch box cover 2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
8.4 After connecting the electrical wiring to the indoor unit To prevent water ingress to the switch box, seal the low voltage wiring intake using the sealing tape (delivered as accessory). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 115
Electrical installation Without low voltage cables With low voltage cables EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
First time – Configuration wizard. When you turn ON the user interface for the first time (via the indoor unit), the configuration wizard starts to help you configure the system. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Confirm the pin code and proceed. Installer pin code The Installer pin code is 5678. Additional menu items and installer settings are now available. Installer 5678 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 118
4 Turn the left dial to select the second part of the setting 01 15 5 Turn the right dial to modify the value from 15 to 20. 01 20 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] Hysteresis [5.9] and [5.A] 9.3 Possible screens 9.3.1 Possible screens: Overview The most common screens are as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
26 Feb 2019 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 122
Outdoor unit Indoor unit / domestic hot water tank Floor-standing indoor unit with integrated tank Wall-mounted indoor unit Wall-mounted indoor unit with separated tank Water pressure EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 123
"13.4.1 To display the help text in case of a malfunction" [ 224] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
°C °C – – Tank Additional zone Explanation – Possible actions on this screen Go through the list of the submenu. Go to the submenu. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
INFORMATION The procedures to program other schedules are similar. To program the schedule: overview Example: You want to program the following schedule: User defined 1 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 127
1 Select the day of which you want to clear the content. For example Friday User defined 1 2 Select Delete. Delete Edit Copy 3 Select OK to confirm. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 128
To copy the schedule to the other weekdays 1 Select Monday. User defined 1 2 Select Copy. Delete Edit Copy Result: Next to the copied day, "C" is displayed. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 129
8:00 21°C 23:00 18°C --:-- 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. 8 Select Paste. Result: User defined 1 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
See "9.4.4 Using weather-dependent curves" [ 133]. 9.4.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Examples Weather-dependent curve when slope is selected: Weather-dependent curve when offset is selected: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
9.4.4 Using weather-dependent curves Configure weather-dependent curves as following: To define the setpoint mode To use the weather-dependent curve, you need to define the correct setpoint mode: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 134
To fine-tune the weather-dependent curve: slope-offset curve The following table describes how to fine-tune the weather-dependent curve of a zone or tank: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
To display the error code, open the menu screen and go to [0] Malfunctioning. Press more information about the error. User profile Operation Malfunctioning Room Main zone EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Room frost protection, when enabled, is not guaranteed when there is no room thermostat that can activate the heat pump. This is the case when: ▪ [2.9] Control=External room thermostat and [C.2] Space heating/ cooling=Off, or if EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 137
Space heating/cooling=On, and The unit will supply leaving water to the heat emitters to heat up the room ▪ Operation mode=Heating according to normal logic. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 138
▪ Outdoor temperature drops below 6°C ▪ Space heating/cooling=On, and There is no room frost protection. ▪ Operation mode=Cooling Room thermostat control ([C‑07]=2) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 139
Human Comfort Interface or the external room sensor cannot be installed at the ideal location. "5.7 Setting up an external temperature sensor" [ 53]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
▪ In Weather dependent LWT setpoint mode, the scheduled actions consist of desired shift actions, either preset or custom. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 141
131] and "9.4.3 Slope-offset curve" [ 132]. Code Description [2.E] ▪ 2-points ▪ Slope-Offset Heating WD curve Set weather-dependent heating for the main zone (if [2.4]=1 or 2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 142
Note: This value should be lower than [1‑02] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the main zone (if [2.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 143
It is important to set Emitter type correctly and in accordance with your system layout. The target delta T for the main zone depends on it. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 144
Setpoint range To prevent a wrong (i.e. too hot or too cold) leaving water temperature for the main leaving water temperature zone, limit its temperature range. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 145
▪ Otherwise: 37°C~55°C [2.8.3] [9-02] Cooling minimum: ▪ 5°C~18°C [2.8.4] [9-03] Cooling maximum: ▪ 18°C~22°C Control Define how the operation of the unit is controlled. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 146
Delta T is the absolute value of the temperature difference between the leaving water and entering water. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 147
Additionally, also the desired leaving water temperature must be configured: if Modulation is enabled, the unit automatically calculates the desired leaving water temperature. These calculations are based on: ▪ the preset temperatures, or EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 148
1 leaving water temperature zone, connect the shut-off valve to the heating/cooling output. The shut off valve for the main leaving water temperature zone can close under these circumstances: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
▪ 1 Yes: closes when the space operation mode is cooling. 9.5.4 Additional zone Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 150
126]. Setpoint mode The setpoint mode of the additional zone can be independently set from the setpoint mode of the main zone. "Setpoint mode" [ 141]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 151
Also see "9.5.3 Main zone" [ 140]. Code Description [2.E] ▪ 2-points ▪ Slope-Offset Heating WD curve Set weather-dependent heating for the additional zone (if [3.4]=1 or 2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 152
Note: This value should be lower than [0‑01] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the additional zone (if [3.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 153
[9‑05]~[9‑06] [1‑0C] 0: Underfloor Maximum 55°C Variable (see [3.B.1]) heating 1: Fancoil unit Maximum 55°C Variable (see [3.B.1]) 2: Radiator Maximum 70°C Fixed 10°C EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 154
(X2M/35a) ▪ 2: 2 contacts. Connected to 2 digital inputs (X2M/34a and X2M/35a) Leaving water temperature: Delta T For more information, see "9.5.3 Main zone" [ 140]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
To tell the system which space operation to use, you can: You can… Location Check which space operation mode is currently used. Home screen EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 156
Cooling only: Restricted 4 Confirm the changes. Example: Changeover restrictions When Restriction During cold season. Heating only Example: October, November, December, January, February and March. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 157
(thus 24+1=25°C) and the desired heating temperature added by the offset value (thus 22+4=26°C). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 158
LWT zone. Code Description [4.4] [7‑02] ▪ 0: Single zone Only one leaving water temperature zone: a Main LWT zone EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 159
When the space heating/cooling operation is OFF, the pump is always OFF. When space heating/cooling operation is ON, you have the choice between these operation modes: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 160
Sample is ONLY available in leaving water temperature control. a Space heating/cooling control b Off c On d LWT temperature e Actual f Desired g Pump operation EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 161
With this limitation range, delta T is possible and the comfort is guaranteed. The maximum values depend on the unit type: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 162
Use this setting to compensate for possible heat losses of the building due to the evaporation of melted ice or snow. (e.g. in cold region countries). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Room frost protection [1.4] prevents the room from getting too cold. For more information about room frost protection, see "9.5.2 Room" [ 136]. 9.5.6 Tank Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 164
When powerful operation is active, the risk of space heating/cooling and capacity shortage comfort problems is significant. In case of frequent domestic hot water operation, frequent and long space heating/cooling interruptions will happen. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 165
The domestic hot water can be prepared in 3 different ways. They differ from each other by the way the desired tank temperature is set and how the unit acts upon it. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 167
The maximum temperature that users can select for the domestic hot water. You can use this setting to limit the temperatures at the hot water taps. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Tank [7.1] Language User settings [7.2] Time/date Information Installer settings [7.3] Holiday [7.4] Quiet [7.5] Electricity price [7.6] Gas price Language Code Description [7.1] Language EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 171
Confirm the changes. 3 Set the last day of your holiday. — ▪ Go to [7.3.3]: Till. ▪ Select a date. ▪ Confirm the changes. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 172
126]. Electricity prices and gas price Only applicable in combination with the bivalent function. See also "Bivalent" [ 189]. Code Description [7.5.1] Electricity price > High EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 173
2 Program the selection using the scheduling screen. You can set — the High, Medium and Low electricity prices according to your electricity supplier. 3 Confirm the changes. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 174
Gas price=8.58 Calculation of the electricity price Electricity price=Actual electricity price+Incentive/kWh Electricity price=12.49+5 Electricity price=17.49 Price Value in breadcrumb Gas: 4.08 /kWh [7.6]=8.6 Electricity: 12.49 /kWh [7.5.1]=17 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Room, tank or domestic hot water, outside, and leaving water temperature (if applicable) [8.5] Actuators Status/mode of each actuator Example: Domestic hot water pump ON/OFF EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Afterwards, more detailed settings can be done via the menu structure if required. To restart the configuration wizard, go to Installer settings > Configuration wizard [9.1]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 177
When measuring the resistance value of each heater, you can set the exact heater capacity and this will lead to more accurate energy data. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 178
Only for systems with integrated domestic hot water tank: If the storage temperature setpoint is higher than 50°C, Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the required time for the unit to heat up the domestic hot water tank.
Page 179
Only for systems with integrated domestic hot water tank: If backup heater operation during space heating needs to be limited but can be allowed for domestic hot water operation, then set [4‑00] to 2. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 180
Glycol Filled system: Is the system filled with glycol? ▪ 0: No ▪ 1: Yes Balancing Priorities For systems with an integrated domestic hot water tank. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 181
[8-02] Heat pump domestic water heating mode (1=active, 0=not active) Hot water request for heat pump (1=request, 0=no request) Time [8-04]: Additional timer at [4-02]/[F-01] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 182
Only relevant for installations with water piping outdoors. This function tries to protect outdoor water piping from freezing. Code Description [9.7] [4-04] Water pipe freeze prevention: ▪ 0: Intermittent (read only) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 183
Therefore, always enable the auto restart function. ▪ 3 Safety thermostat: A safety thermostat is connected to the system (normal closed contact) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 184
▪ 0 Amp: The limitation values are set in A. ▪ 1 kW: The limitation values are set in kW. Limit when [9.9.1]=Continuous and [9.9.2]=Amp: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 186
(BBR16 activation and BBR16 power limit). After 2 weeks, the unit freezes these settings. Note: This is different from the permanent power limitation, which is always changeable. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 188
The outdoor temperature is averaged over the selected time period. Code Description [9.B.3] [1-0A] Averaging time: ▪ 0: No averaging ▪ 1: 12 hours ▪ 2: 24 hours ▪ 3: 48 hours ▪ 4: 72 hours EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 189
Space heating by the heat Bivalent signal for the pump system… auxiliary boiler is… Drops below T Stops Active calc Rises above T +3°C Starts Inactive calc EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 190
2 Determine the value of [C‑03] using the graph. For an example, see the table legend. 2.5 (a) 10.5 (b) [C‑03]=2.5 in case of COP=3 and LWT=35°C [C‑03]=10.5 in case of COP=3 and LWT=55°C EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 191
See also table below (Alarm output logic). Alarm output logic [C-09] Alarm No alarm No power supply to unit Closed output Open output Open output Open output Closed output EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 192
Afterwards: An installer can manually disable the protective functions by setting [9.G]: Disable protections=Yes. After his work is done, he can enable the protective functions by setting [9.G]: Disable protections=No. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 193
▪ Back ▪ To export MMI settings 1 Open the user interface panel and insert a USB memory stick. — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
[C.1] Room: ▪ 0: Off ▪ 1: On [C.2] Space heating/cooling: ▪ 0: Off ▪ 1: On [C.3] Tank: ▪ 0: Off ▪ 1: On EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
[D.4] Device info About the WLAN adapter The wireless LAN adapter connects the heat pump system to the internet. The user can then control the heat pump system via the Daikin Residential Controller app. This needs the following components: WLAN adapter...
Page 196
Reset the gateway: ▪ Back ▪ Device info: Consult information about the WLAN adapter. Code Description [D.4] Device info: ▪ SSID ▪ MAC address ▪ Serial number EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Only accessible by installer (***) Only applicable when WLAN adapter is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
10 Commissioning NOTICE General commissioning checklist. Next to the commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a guideline and reporting template during the commissioning and hand-over to the user.
There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units. Backup heater circuit breaker F1B (field supply) is turned ON. The correct pipe size is installed and the pipes are properly insulated. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
When the air purge function is running, the pump operates without actual operation of the unit and the removal of air in the water circuit will start. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 202
3 In the menu, set Type = Manual. 4 Select Start air purge. 5 Select OK to confirm. Result: The air purge starts. It stops automatically when ready. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
"To change — the user permission level" [ 117]. 2 Go to [A.1]: Commissioning > Operation test run. 3 Select a test from the list. Example: Heating. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
1 In the menu, go to Stop test run. 2 Select OK to confirm. Possible actuator test runs ▪ Backup heater 1 test ▪ Backup heater 2 test ▪ Pump test EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
1 the duration in hours, up to 72 hours, 2 the desired leaving water temperature, up to 55°C. Example: 24h (1) 36h (2) 35°C (2) 25°C (1) Desired leaving water temperature (15~55°C) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 206
[D‑01]=0 ▪ [4‑08]=0 ▪ [4‑01]≠1 Steps Conditions: An underfloor heating screed dryout schedule has been programmed. "To program an underfloor heating screed dryout schedule" [ 205]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 207
1 Go to [A.4.3]: Commissioning > UFH screed dryout > Status 2 You can read out the value here: Stopped at + the step — where the underfloor screed dryout was stopped. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 208
If the UFH screed dryout program was stopped due to a power failure and the power resumes, the program will automatically restart the last implemented step. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Before performing any maintenance or service work, touch a metal part of the unit in order to eliminate static electricity and to protect the PCB. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Switch box ▪ Descaling ▪ Chemical disinfection 12.3.4 Yearly maintenance indoor unit: instructions Water pressure Keep water pressure above 1 bar. If it is lower, add water. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 212
"12.5.3 To install the water filter" [ 216] Water pressure relief valve Open the valve and check if it operates correctly. The water may be very hot! Checkpoints are: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 213
For this reason, descaling of the heat exchanger may be required at certain intervals. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
▪ "12.5.1 To remove the water filter" [ 215] ▪ "12.5.2 To clean the water filter in case of trouble" [ 215] ▪ "12.5.3 To install the water filter" [ 216] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Opening the magnetic filter/dirt separator is ONLY required in case of severe issues. Preferably this action is never to be done during the complete lifetime of the magnetic filter/dirt separator. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Check the condition of the O-rings and replace if needed. Apply water to the O-rings before installation. 1 Install the water filter in the correct location. Clip Magnetic filter/dirt separator EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 217
Make sure to open the valve (if equipped) towards the expansion vessel, otherwise the overpressure will be generated. 5 Open the stop valves and add water to the water circuit if needed. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
If you are unable to find the cause of the problem, call your dealer. DANGER: RISK OF ELECTROCUTION EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Make sure that the water volume in the too low installation is above the minimum required value (see "7.1.3 To check the water volume and flow rate" [ 76]). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
We recommend to purge air with the air purge function of the unit (to be performed by the installer). If you purge air from the heat emitters or collectors, mind the following: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Purge air manually (see "To perform a manual air purge" [ 202]) or use the automatic air purge function (see "To perform an automatic air purge" [ 203]). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
▪ If the water keeps running out of the unit, close both the water inlet and outlet shut-off valves first and then contact your dealer. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
13.4.1 To display the help text in case of a malfunction In case of a malfunction, the following will appear on the home screen depending on the severity: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Overheating water circuit (thermostat) A1-00 Zero cross detection problem A5-00 OU: High pressure peak cut / freeze protection problem AA-01 Backup heater overheated AC-00 Booster heater overheated EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 226
OU: Malfunction of compressor input (CT) system H9-00 OU: Malfunction of outdoor air thermistor HC-00 Tank temperature sensor problem HC-01 Second tank temperature sensor problem EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 227
OU: Defect of power supply voltage U3-00 Underfloor heating screed dryout function not completed correctly U4-00 Indoor/outdoor unit communication problem U5-00 User interface communication problem EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 228
If the software is not successfully updated then you must make sure that your USB device has the FAT32 format. INFORMATION The user interface of the indoor unit will display how to reset an error code. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
See: ▪ "6.3.6 To install the discharge grille" [ 68] ▪ "6.3.7 To remove the discharge grille, and put the grille in safety position" [ 69] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 230
3 Turn the EEV magnet clockwise to the fully open position of the valve. If you are not sure about what the open position is, turn the valve in its middle position so that refrigerant can pass. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Technical data 15 Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). In this chapter 15.1...
Right side view See note *** See note *** Notes: Symbols: Live Neutral Protective earth Noiseless earth Field wiring Option Terminal strip Terminal Connector Connection EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 236
Light-emitting diode (service monitor is orange) HAP (A1P) Light-emitting diode (service monitor is green) K1R (A1P) Magnetic relay (Y1S) K1R (A4P) Magnetic relay (E1HHEX~E3HHEX) K2R (A1P) Magnetic relay (Y2S) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Safety thermostat Safety thermostat Main LWT Main leaving water temperature On/OFF thermostat (wired) On/OFF thermostat (wired) On/OFF thermostat (wireless) On/OFF thermostat (wireless) Ext. thermistor External thermistor EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 241
# 2-way valve for cooling mode PC (A15P) * Power circuit PHC1 (A4P) * Optocoupler input circuit Thermal protector backup heater # Safety thermostat Q*DI # Earth leakage circuit breaker EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 242
Only for remote user interface HCI Only for the dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) Only for WLAN adapter Only for WLAN adapter SWB1 Switch box EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 243
(8) External On/OFF thermostats and heat pump convector heat pump convector Additional LWT zone Additional leaving water temperature zone Main LWT zone Main leaving water temperature zone EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 244
Only for heat pump convector Only for wired On/OFF thermostat Only for wired On/OFF thermostat Only for wireless On/OFF thermostat Only for wireless On/OFF thermostat EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Page 245
A20P: J2 2 core 2×0.75 communication A11P: X9: 1-2-3 X5M: 11-12 A14P: P1-P2 user interface communication 2 core 2×0.75 A13P: P1-P2 LAN adapter communication 4D124705A EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1A – 2020.01...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Page 248
2/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value Room └─ Antifrost 1.4.1 [2-06] Activation 0: Disabled 1: Enabled 1.4.2 [2-05] Room setpoint 4~16°C, step: 1°C 8°C └─...
Page 249
3/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value └─ Heating WD curve [0-00] Leaving water value for high ambient temp. for LWT add zone heating WD curve. [9-05]~min(45,[9-06])°C, step: 1°C [2-0C]=0 25°C...
Page 250
4/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value └─ Disinfection 5.7.1 [2-01] Activation 0: No 1: Yes 5.7.2 [2-00] Operation day 0: Each day 1: Monday 2: Tuesday 3: Wednesday 4: Thursday...
Page 251
5/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.1.4.4 [6-04] Additional capacity step 2 0~10kW, step: 0,2kW 4kW (*1) 6kW (*2) └─ Main zone 9.1.5.1 [2-0C] Emitter type 0: Underfloor heating...
Page 252
6/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.2.1 [E-05] Domestic hot water No DHW (*3) [E-06] EKHW (*3) [E-07] Integrated (*4) EKHWP (*3) 9.2.2 [D-02] DHW pump 0: No DHW pump...
Page 253
7/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.9.B [5-0B] Limit 3 0~20 kW, step: 0,5 kW 20 kW 9.9.C [5-0C] Limit 4 0~20 kW, step: 0,5 kW 20 kW 9.9.D [4-01]...
Page 254
8/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [1-02] Leaving water value for low ambient temp. for LWT main zone heating WD curve. [9-01]~[9-00], step: 1°C [2-0C]=0 35°C [2-0C]=1...
Page 255
9/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [4-01] Which electric heater has priority? 0: None 1: BSH 2: BUH [4-02] Below which outdoor temperature is heating allowed? 14~35°C, step: 1°C 35°C [4-03]...
Page 256
10/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [7-03] [7-04] [7-05] Boiler efficiency 0: Very high 1: High 2: Medium 3: Low 4: Very low [7-06] HP Forced OFF 0: Disabled...
Page 257
11/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [D-01] Contact type of preferential kWh rate PS installation? 0: No 1: Active open 2: Active closed 3: Safety thermostat [D-02] Which type of DHW pump is installed?
Page 260
4P587502-1A 2020.01 Verantwortung für Energie und Umwelt...