8.

Operation

8.1.

Display during operation

8.2.

Display during regeneration

During regeneration, the regeneration cycle wheel shows the regeneration step the valve is advancing
to, or has reached (green), and the time remaining in that step (1). Once all regeneration steps are
complete the valve returns to treatment position and resumes normal operation. The time remaining
in each regeneration step will be displayed on the home screen in hours and minutes.
Pressing the
button during a regeneration cycle immediately advances the valve to the next cycle
step position and resumes normal step timing. The
position and the motor has stopped.
Pressing
will cancel regeneration and the valve will return to treatment position.
8.3.

Controller operation during programming

The controller can only be programmed with the valve in treatment. While being programmed the
controller continues to operate normally, monitoring water usage and keeping all displays up to date.
Controller programming is stored in memory permanently until reset.
94 / 124
Water treatment
wed
12:01 am
treatment
tank refill
rapid rinse
Regeneration
treatment
tank refill
rapid rinse
4.5
3
m
backwash
draw
48 m
34 s
backwash
draw
button is only available when the valve is in
Ref. MKT-IM-018 / C - 08.06.2018

Advertisement

Table of Contents
loading

Table of Contents