Pentair FLECK 5600 Service Manual
Hide thumbs Also See for FLECK 5600:

Advertisement

FLECK 5600
SERVICE MANUAL
waterpurification.pentair.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5600

  • Page 1 FLECK 5600 SERVICE MANUAL waterpurification.pentair.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS JOB SPECIFICATION SHEET JOB SPECIFICATION SHEET ..........2 Job Number: ______________________________________________ INSTALLATION ..............3 Model Number: ____________________________________________ START-UP INSTRUCTIONS..........4 Water Hardness: __________________________________ ppm or gpg MODEL 5600 INSTALLATION AND Capacity Per Unit: __________________________________________ START-UP PROCEDURES ............4 Mineral Tank Size: ___________ Diameter: ________Height: ________ MODEL 5600 BACKWASH FILTER INSTALLATION AND Salt Setting per Regeneration: ________________________________ START-UP PROCEDURES ............5...
  • Page 3: Installation

    INSTALLATION check (Figure 1) in the salt tank. Do not add salt to the brine tank at this time. Water Pressure 10. On units with a by-pass, place in bypass position. Turn on A minimum of 25 psi (1.7 bar) of water pressure is required the main water supply.
  • Page 4: Start-Up Instructions

    START-UP INSTRUCTIONS MODEL 5600 INSTALLATION AND START-UP PROCEDURES The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the NOTE: Install the water softener with the inlet, outlet, and manufacturer’s recommendations, and to meet applicable drain connections made according to manufacturer's plumbing codes.
  • Page 5: Model 5600 Backwash Filter Installation And Start-Up Procedures

    MODEL 5600 BACKWASH FILTER Cycle Times and Flow Diagrams 1. In Service position. See page 7. INSTALLATION AND START-UP 2. Preliminary Rinse position. PROCEDURES • See page 7 with standard piston (white end plug) or filter piston (black end plug). NOTE: Install the water softener with the inlet, outlet, and drain connections made according to manufacturer's •...
  • Page 6: Model 5600 Installation And Start-Up Procedures

    MODEL 5600 INSTALLATION AND START- allow the control to draw water from the brine tank until it stops.Plug in the electrical cord and look in the sight hole in UP PROCEDURES the back of the monitor to see that it is running. NOTE: Install the water softener with the inlet, outlet, and 9.
  • Page 7: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS Service Position Backwash Position Preliminary Rinse Position Brine Position FLECK • 7 5600 Service Manual...
  • Page 8 WATER CONDITIONER FLOW DIAGRAMS CONTINUED Slow Rinse Position Settling Rinse Position Second Backwash Position Brine Tank Fill Position 8 • FLECK 5600 Service Manual...
  • Page 9 [ THIS PAGE LEFT INTENTIONALLY BLANK ] FLECK • 9 5600 Service Manual...
  • Page 10: Model 5600 Control Valve Drive Assembly

    MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY 10 • FLECK 5600 Service Manual...
  • Page 11 MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 34 ....2 ..12473 ....Screw-drive Mounting 1 ....1 ..14448-001 ..Drive Housing, with Pin Drilled for Cover 35s ..1 ..12037 ....Washer 1A ....1 ..15494-01 ..“L” Housing, with Pin 37 ....1 ..
  • Page 12 MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY Backwash Filter Injector Option 3 16 15 1 23 24 12 • FLECK 5600 Service Manual...
  • Page 13 MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 37 ....1 ..10332 ....BLFC Tube Insert 1 .... 2-4 ..13255 ....Adapter Clip (Clock or Meter) 38 ....1 ..12094 ....BLFC Button, .25 gpm 2 ....5 ..
  • Page 14 MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY 14 • FLECK 5600 Service Manual...
  • Page 15 MODEL 5600 CONTROL VALVE DRIVE ASSEMBLY CONTINUED Item No. Part No. Description Item No. Part No. Description 40 ....1 ..14276 ....Spring 1 ....1 ..14488-001 ..Drive Housing, with Pin Drilled for Cover 41 ....1 ..14043 ....Cable Assembly, Standard 1A ....1 ..
  • Page 16: 5600 Electromechancial

    5600 ELECTROMECHANCIAL Softener Time Clock Softener Meter Item No. Part No. Description Item No. Part No. Description 1 ....1 ..560001-003 ... 5600, SOF, DFN, CLK, 12DA, 12060, 1 ....1 ..560002-001 ... 5600, SOF, DFN, M34, MDEL, 12060, CW 1--, .50, LES, NA2, 1600, SOFT CW 1--, .50, LES, NA2, 1600, SOFT ..
  • Page 17: 5600 Valve Accessories

    5600 VALVE ACCESSORIES Covers 13753-02 .....Cover, 5600, Black 42345-03 .....Cover, 5600, Mechanical, Smoke 42345-04 .....Cover, 5600, Mechanical, Transparent Blue 60226-11 .....Cover, 5600, Designer I, Blk/Blk 60226-22 .....Cover, 5600, Designer I, Blue/Blue Bypasses COVER COVER, MECHANICAL 60041SS.......1” Bypass, SS, NPT 60040SS.......3/4” Bypass, SS, NPT 60049 ......Bypass, Plastic Yokes 19620-01 .....Yoke Assy, 3/4", r/angle, 90 deg.
  • Page 18: 5600 Valve Assemblies

    5600 VALVE ASSEMBLIES BLFC 60022-12 .....BLFC, 0.125 GPM (0.375 lbs NaCl/min) 60022-25 .....BLFC, 0.25 GPM (0.75 lbs NaCl/min) 60022-50 .....BLFC, 0.50 GPM (1.5 lbs NaCl/min) 60022-100 ....BLFC, 1.0 GPM (3 lbs NaCl/min) Injector Drain Assemblies 60084-0001 ....Injector Drain Assy, 5600, #0, Blank DLFC, .25 BLFC BLFC INJECTOR DRAIN ASSY 60084-0002 ....Injector Drain Assy,...
  • Page 19 5600 VALVE ASSEMBLIES Labels 14213 ......Label, 11.5K 14214 ......Label, 13K 14343 ......Label, 15K 14076 ......Label, 16K 13969 ......Label, 18K 14046 ......Label, 21K 13961 ......Label, 24K 14237 ......Label, 24K, Black LABEL, HARDNESS LABEL, LBS. OF SALT 14047 ......Label, 26K 14180 ......Label, 28K 13962 ......Label, 30K 14048 ......Label, 32K 13971 ......Label, 36K...
  • Page 20 5600 VALVE ASSEMBLIES CONTINUED Powerheads 62089-01 .....Pwrhd, 5600, Soft, Mtr, Srng, Encl, Orange, 120/60, US Cord 62089-02 .....Pwrhd, 5600, Soft, Mtr, Srng, Encl, Sil/Blu, 24/60, XFMR120/24 62089-03 .....Pwrhd, 5600, Soft, Mtr, Srng, Encl, Sil/Blu, 120/60, US Cord 62089-04 .....Pwrhd, 5600, Soft, Mtr, Srng, Encl, Sil/Blu, 24/60, No Cord POWERHEAD PROGRAM WHEEL...
  • Page 21: Service Instructions

    SERVICE INSTRUCTIONS Replace Timer 1. Unplug electrical cord from outlet. Replace Time Brine Valve, Injectors and Screen 2. Turn off water supply to conditioner: 1. Unplug electrical cord from outlet. A. If the conditioner installation has a “three valve” bypass 2.
  • Page 22 SERVICE INSTRUCTIONS CONTINUED B. If the conditioner has an integral bypass valve, put it in the Bypass position. Replace Piston Assembly C. If there is only a shut-off valve near the conditioner inlet, close it. 1. Unplug electrical cord from outlet. 3.
  • Page 23 SERVICE INSTRUCTIONS CONTINUED Replace Meter Cover and/or Impeller 1. Unplug electrical cord from outlet. 2. Turn off water supply to conditioner: A. If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the valves at the conditioner inlet and outlet.
  • Page 24: Troubleshooting

    TROUBLESHOOTING Problem Cause Correction 1. Softener fails to A. Electrical service to unit has been interrupted. A. Assure permanent electrical service regenerate. (check fuse, plug, pull chain or switch). B. Timer is defective. B. Replace timer. C. Power failure. C. Reset time of day. 2.
  • Page 25: General Service Hints For Meter Control

    GENERAL SERVICE HINTS FOR METER CONTROL Problem Cause Correction 1. Softener delivers A. Reserve capacity has been exceeded. A. Check salt dosage requirements and reset hard water. program wheel to provide additional reserve. B. Program wheel is not rotating with meter B.
  • Page 26 26 • FLECK 5600 Service Manual...
  • Page 27 FLECK • 27 5600 Service Manual...
  • Page 28 For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com/brands. § Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners.

Table of Contents