Pentair FLECK 5810 SXT UPFLOW/DOWNFLOW Service Manual
Pentair FLECK 5810 SXT UPFLOW/DOWNFLOW Service Manual

Pentair FLECK 5810 SXT UPFLOW/DOWNFLOW Service Manual

Hide thumbs Also See for FLECK 5810 SXT UPFLOW/DOWNFLOW:

Advertisement

Quick Links

FLECK 5810 & 5812 SXT UPFLOW/DOWNFLOW
SERVICE MANUAL
5810
5812
waterpurification.pentair.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5810 SXT UPFLOW/DOWNFLOW

  • Page 1 FLECK 5810 & 5812 SXT UPFLOW/DOWNFLOW SERVICE MANUAL 5810 5812 waterpurification.pentair.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS JOB SPECIFICATION SHEET JOB SPECIFICATION SHEET ............ 2 Job Number: ___________________________________________________ INSTALLATION ................. 3 Model Number: _________________________________________________ Water Hardness: _______________________________________ ppm or gpg START-UP INSTRUCTIONS ............4 Capacity Per Unit: _______________________________________________ CONTROL FEATURES .............. 4 Mineral Tank Size: ______________ Diameter: ________ Height: _________ USER PROGRAMMING .............
  • Page 3: Installation

    INSTALLATION NOTE: The tank should have the distributor tube installed and Water Pressure have the proper amount of regenerant in place. A minimum of 20 psi (1.4 bar) of water pressure is required for 4. Refer to the spec sheet for cutting height of the distributor the regeneration valve to operate effectively.
  • Page 4: Start-Up Instructions

    START-UP INSTRUCTIONS Features of the SXT: The water softener should be installed with the inlet, • Power backup that continues to keep time and the outlet, and drain connections made in accordance with the passage of days for a minimum of 8 hours in the event of manufacturer’s recommendations, and to meet applicable power failure.
  • Page 5: User Programming

    USER PROGRAMMING 4. Press the Extra Cycle button. Use this display to adjust the The SXT control was designed to operate under most Feed Water Hardness. This option setting is identified by conditions with minimal programming. Follow the procedure "H" in the upper left hand corner of the screen. below to set up the control for normal operation.
  • Page 6: Control Operation

    CONTROL OPERATION Manually Initiating a Regeneration Meter Immediate Control 1. When the system is in service, press the Extra Cycle button A Meter Immediate control measures water usage and for five seconds on the main screen. regenerates the system as soon as the calculated system 2.
  • Page 7: Master Programming Mode Chart

    MASTER PROGRAMMING MODE CHART Before entering Master Programming, please CAUTION contact your local professional water dealer. Master Programming Options Abbreviation Parameter Option Abbreviation Options Display Format Gallons Liters Valve Type 5810 5810 Control Valve 5812 5812 Control Valve Regenerant Flow dF1b Standard Downflow Single Backwash dF2b...
  • Page 8: Regenerant Flow

    MASTER PROGRAMMING MODE 1. Display Format (Display Code DF) When Master Programming Mode is entered, all available option setting displays may be viewed and set as needed. This is the first screen that appears when entering Master Depending on current option settings, some parameters Programming Mode.
  • Page 9 MASTER PROGRAMMING MODE continued 4. Control Type (Display Code CT) 7. Reserve Selection (Display Code RS) Press the Extra Cycle button. Use this display to set the Control Press the Extra Cycle button. Use this display to set the Safety Type.
  • Page 10 MASTER PROGRAMMING MODE continued 10. Day Override (Display Code DO) If the system has been configured with the "Other" valve type, the regeneration cycles will be identified as C1, C2, ..., C20. Press the Extra Cycle button. Use this display to set the Day Cycle steps can be programmed in any order using the Up or Override.
  • Page 11 MASTER PROGRAMMING MODE continued 14. Current Day (Display Code CD) Press the Extra Cycle button. Use this display to set the current day on systems that have been configured as Day of Week controls. This setting is identified by "CD" in the upper left- hand corner of the screen.
  • Page 12: Viewing Diagnostic Data

    VIEWING DIAGNOSTIC DATA 4. Press the Up button. Use this display to view the Hours The SXT control records and maintains diagnostic data to assist with servicing and troubleshooting the water treatment system. in Service since the last regeneration cycle. This option setting is identified by "HR"...
  • Page 13: System Disinfection

    SYSTEM DISINFECTION INSTALLATION CHECKLIST Disinfection Of Water Softeners Read the owner's/installation manual?  The materials of construction of the modern water softener Follow all safety guidelines in the manual?  will not support bacterial growth, nor will these materials  If metal pipe was used, did you restore the electrical ground? contaminate a water supply.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Error Codes NOTE: Error codes appear on the In Service display. Error Code Error Type Cause Reset and Recovery ---0 Motor Stall /Cam No state changes in the optical Unplug the unit and plug back in. Allow the control to attempt to find Sense Error sensor are detected for six position again.
  • Page 15: Powerhead Assembly

    POWERHEAD ASSEMBLY Item No. Item No. Part No. Part No. Description Description 1....1....1 ..61832-01 ....Cover Assembly, Black/Black 2....1 ..61957-02 ....Panel Gear Assembly, Upflow/ Downflow 3....1 ..61834 ....Timer Assembly, SXT 4....1 ..61835 ....Motor Assembly 5....1 ..61994 ....Cover Assembly, Environmental 6....1 ..
  • Page 16: 5810 Control Valve Assembly

    5810 CONTROL VALVE ASSEMBLY Item No. Part No. Description 1 ....1 ..61961 ....Kit, Mounting, 5810/5812 2 ....1 ..61956-01 ....Kit, Piston, Seal, and Spacer, 5810/5812, Downflow ......... 61956-02 ....Kit, Piston, Seal, and Spacer, 5810/5812, Upflow .........
  • Page 17: 5812 Control Valve Assembly

    5812 CONTROL VALVE ASSEMBLY Item No. Part No. Description 1....1 ..61961 ....Kit, Mounting, 5810/5812 2....1 ..61956-01 ....Kit, Piston, Seal, and Spacer, 5810/5812, Downflow ......61956-02 ....Kit, Piston, Seal, and Spacer, 5810/5812, Upflow ......61956-03 ....Kit, Piston, Seal, and Spacer, 5810/5812, Filter 3....1 ..
  • Page 18: 5812 Drain Line Flow Controls

    5812 DRAIN LINE FLOW CONTROLS Item No. Part No. Description Item No. Part No. Description 2 ....... 61977-00 ....DLFC, 1.25", NPT, Blank, 5812 1 ....1 ..61971-00 ....DLFC, 1", NPT, Blank, 5812 ..61977-1.7 ....DLFC, 1.25", NPT, 1.7 GPM, 5812 ..
  • Page 19: Bypass Assembly

    BYPASS ASSEMBLY 43644 REV A Item No. Part No. Description 1....1 ..43644 ....Bypass Assembly, 1.25", 5810/12 Not Shown: 1 ..61991 ....Connector Assy 1 ..61991-01 ....Connector Assy, 1" NPT 1 ..61991-02 ....Connector Assy, 1" BSP 1 ..61991-03 ....Connector Assy, 1-1/4" NPT 1 ..
  • Page 20: Safety Brine Valve

    SAFETY BRINE VALVE 42112 Rev A Item No. Part No. Description 1....1 ..19645 ....Body, Safety Brine Valve, 2310 2....1 ..19803 ....Safety Brine Valve Assy 3....1 ..19804 ....Screw, Sckt Hd, Set, 10-24 x 0.75 4....1 ..19805 ....Nut, Hex, 10-24, Nylon Black 5....1 ..
  • Page 21: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS 3. BACKWASH POSITION 5810 Upflow 1. SERVICE POSITION 4. RAPID RINSE POSITION BRINE CAM BRINE VALVE 2. BRINE/SLOW RINSE POSITION DRAIN BRINE LINE INLET BRINE LINE INLET AIR CHECK BRINE TANK RESIN TANK 5. BRINE TANK REFILL POSITION BRINE LINE INLET BRINE TANK...
  • Page 22 WATER CONDITIONER FLOW DIAGRAMS 3. BRINE/SLOW RINSE POSITION continued 5810 Downflow 1. SERVICE POSITION BRINE LINE INLET 4. RAPID RINSE POSITION BRINE CAM BRINE VALVE DRAIN BRINE LINE 2. BACKWASH POSITION INLET AIR CHECK BRINE TANK RESIN TANK 5. BRINE TANK REFILL POSITION BRINE LINE INLET BRINE TANK...
  • Page 23: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS 3. BACKWASH POSITION 5812 Upflow 1. SERVICE POSITION 4. RAPID RINSE POSITION DRAIN 2. BRINE/SLOW RINSE POSITION BRINE LINE INLET 5. BRINE TANK REFILL POSITION BRINE LINE INLET BRINE TANK RESIN TANK FLECK 5810 & 5812 SXT Upflow/Downflow • 23...
  • Page 24 WATER CONDITIONER FLOW DIAGRAMS 3. BRINE/SLOW RINSE POSITION continued 5812 Downflow 1. SERVICE POSITION BRINE LINE INLET 4. RAPID RINSE POSITION DRAIN 2. BACKWASH POSITION 5. BRINE TANK REFILL POSITION BRINE LINE INLET BRINE TANK RESIN TANK 24 • FLECK 5810 & 5812 SXT Upflow/Downflow...
  • Page 25: 5810 Dimensional Drawings

    5810 DIMENSIONAL DRAWINGS 71.50 2.815 287.4 11.32 5.75 47.8 1.88 29.6 1.17 140.1 120.3 5.52 4.74 122.4 4.82 91.4 3.60 182.9 7.20 61500-5810LNE REV A FLECK 5810 & 5812 SXT Upflow/Downflow • 25...
  • Page 26: 5812 Dimensional Drawings

    5812 DIMENSIONAL DRAWINGS 5812 2.5" BASE 71.50 2.815 12.0 171.2 6.74 5.51 65.4 2.57 29.6 1.17 91.4 140.08 120.3 3.60 5.515 4.74 182.9 7.20 5812 4" BASE 71.50 2.815 12.0 170.31 6.71 140.1 5.52 65.5 2.58 36.8 1.45 91.4 3.60 140.1 120.3 5.51...
  • Page 27: Injector Flow Data

    INJECTOR FLOW DATA TR18755 REV B FLECK 5810 & 5812 SXT Upflow/Downflow • 27...
  • Page 28 All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice.

This manual is also suitable for:

Fleck 5812 sxt upflow/downflow