Pentair FLECK 5800 LXT Installer Manual
Hide thumbs Also See for FLECK 5800 LXT:
Table of Contents

Advertisement

FLECK
5800 LXT
INSTALLER
MANUAL
WATER PURIFICATION

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5800 LXT

  • Page 1 FLECK 5800 LXT INSTALLER MANUAL WATER PURIFICATION...
  • Page 2: Table Of Contents

    Installer Manual Fleck 5800 - LXT - Table of contents Table of contents Generalities ......... . 7 1.1.
  • Page 3 Installer Manual Fleck 5800 - LXT - Table of contents System sizing ........25 4.1.
  • Page 4 Installer Manual Fleck 5800 - LXT - Table of contents Programming ........48 6.1.
  • Page 5 Installer Manual Fleck 5800 - LXT - Table of contents Maintenance ......... 60 9.1.
  • Page 6 Installer Manual Fleck 5800 - LXT - Table of contents PAGE INTENTIONALLY LEFT BLANK 6 / 88 Ref. MKT-IM-005 / C - 22.05.2018...
  • Page 7: Generalities

    Add. cleaning BLFC procedure. Address change, Bleam information and valve on 22.05.2018 BRY/FIM tank assembly. 1.3. Manufacturer identifier, product Manufacturer: Pentair International LLC Avenue de Sevelin 18 1004 Lausanne Switzerland Product: Fleck 5800 - LXT 1.4. Intended use The device is intended to be used for domestic applications only and it is purpose-built for water treatment.
  • Page 8: Abbreviations Used

    Installer Manual Fleck 5800 - LXT - Generalities 1.5. Abbreviations used BLFC ............Brine Line Flow Controller BV ............Brine Valve DF............Down Flow DLFC ............Drain Line Flow Controller Inj ............Injector QC............Quick Connect Regen ............Regeneration S&S ............Seals & Spacers SBV............
  • Page 9: Procedure For Technical Support

    Pentair Quality System EMEA products benefit, under specific conditions, from a manufacturer warranty that may be invoked by Pentair’s direct customers. Users should contact the vendor of this product for applicable conditions and in case of a potential warranty claim.
  • Page 10: Scan & Service Application

    Installer Manual Fleck 5800 - LXT - Generalities 1.10. Scan & Service application Scan & Service mobile application is the ideal support for the maintenance person in his daily business. A simple scan of an identification (ID) label (1) present on the valve with a smartphone gives an instantaneously access to all updated information related to the product, such as: •...
  • Page 11: Safety

    Installer Manual Fleck 5800 - LXT - Safety Safety 2.1. Safety pictograms definition Caution Warning Warns of a risk of minor injury or major Warns against serious personal injury material damage to the device or and damage to health. environment. Danger...
  • Page 12: Personnel

    Installer Manual Fleck 5800 - LXT - Safety 2.3.1. Personnel Only qualified and professional personnel, based on their training, experience and instruction as well as their knowledge of the regulations, the safety rules and operations performed, are authorized to carry out necessary work. 2.3.2.
  • Page 13: Description

    Installer Manual Fleck 5800 - LXT - Description Description 3.1. Technical specifications Design specifications/ratings Valve body ..........Fiber-reinforced polymer Rubber components ....... EP/EPDM/silicone Valve material certification ....DM174, ACS, CE Weight (valve with controller)....2 kg (max) Recommended operating pressure ..1.4 - 8.6 bar Maximum inlet pressure ......
  • Page 14: Performance Flow Rate Characteristics

    Installer Manual Fleck 5800 - LXT - Description Environmental conditions • Indoor use only; • temperature from 0°C to 52°C; • maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C; • mains supply voltage fluctuations up to ±10% of the nominal voltage. 3.1.1.
  • Page 15: Outline Drawing

    Installer Manual Fleck 5800 - LXT - Description 3.2. Outline drawing Ref. MKT-IM-005 / C - 22.05.2018 15 / 88...
  • Page 16: Description And Components Location

    Installer Manual Fleck 5800 - LXT - Description 3.3. Description and components location Controller LCD screen Mode button Regen button Up button Down button Brine line Injector block Drain line Outlet Mixing device Inlet *Meter Piston Brine valve *Not included in case of timeclock 16 / 88 Ref.
  • Page 17 Installer Manual Fleck 5800 - LXT - Description PAGE INTENTIONALLY LEFT BLANK Ref. MKT-IM-005 / C - 22.05.2018 17 / 88...
  • Page 18: System Regeneration Cycle

    Installer Manual Fleck 5800 - LXT - Description 3.4. System regeneration cycle Note This valve allows to do filtration, down flow and up flow regenerations. 3.4.1. Downflow regeneration cycle (5-cycles operation) Service — normal use Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the raw water being exchanged on the resin beads against sodium ions.
  • Page 19 Installer Manual Fleck 5800 - LXT - Description Note For illustration purpose only. Always verify inlet and outlet marking on the valve. SERVICE NORMAL USE BACKWASH Outlet Inlet Outlet Inlet Drain Valve Valve BRINE DRAW & SLOW RINSE RAPID RINSE Outlet Inlet Outlet...
  • Page 20: Upflow Regeneration Cycle (5-Cycles Operation)

    Installer Manual Fleck 5800 - LXT - Description 3.4.2. Upflow regeneration cycle (5-cycles operation) Service — normal use Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the raw water being exchanged on the resin beads against sodium ions.
  • Page 21 Installer Manual Fleck 5800 - LXT - Description Note For illustration purpose only. Always check for inlet and outlet marking on the valve. SERVICE NORMAL USE BRINE DRAW & SLOW RINSE Outlet Inlet Outlet Inlet Drain Valve Valve From brine tank BACKWASH RAPID RINSE...
  • Page 22: Filter Cycle (3-Cycles Operation)

    Installer Manual Fleck 5800 - LXT - Description 3.4.3. Filter cycle (3-cycles operation) Service — normal use Untreated water is directed down through the media and up through the riser tube. The impurities are retained by the media. The water is filtered as it passes through the media. Backwash —...
  • Page 23: Configurations For Downflow Softener, Upflow Softener And Filter

    Installer Manual Fleck 5800 - LXT - Description 3.5. Configurations for downflow softener, upflow softener and filter 3.5.1. Downflow softener The valve is mounted with the DF piston kit, part number BR61837. The injector is in the upper hole and the plug in the lower hole. 3.5.2.
  • Page 24: Options Available On The Valve

    Installer Manual Fleck 5800 - LXT - Description 3.6. Options available on the valve Mixing device The valve can be equipped with a mixing device (1) whose function is to regulate the hardness of the water at the outlet. The mixing can be set from 0% to 50% of hard water (i.e. 0 turn = 0% of hard water with 100% of treated water and 1-½...
  • Page 25: System Sizing

    Installer Manual Fleck 5800 - LXT - System sizing System sizing 4.1. Recommendations 4.1.1. Injector/DLFC/BLFC-Valve configuration Resin Diameter Injector DLFC BLFC Valve volume type [in] Color Color [gpm] DF [gpm] UF [gpm] 5 - 8 9 - 14 15 - 21 Brown Brown 25 - 28...
  • Page 26 Installer Manual Fleck 5800 - LXT - System sizing The below sizing method can be applied for both residential and industrial softeners. The sizing of a softener must be based upon certain parameters: • inlet water hardness; • peak flow rate and nominal flow rate; •...
  • Page 27: Determining The Required Volume Of Resin

    Installer Manual Fleck 5800 - LXT - System sizing Piping size (internal diameter) Max. flow rate [in] [mm] /h at 3 m/s] 1.25 8.69 13.57 21.20 34.2 49.2 4.2.2. Determining the required volume of resin When sizing a softener, make sure that the volume of resin in the tank (bed volume) will be sufficient so that even when the peak flow rate is reached, the velocity is still between the above values depending on the hardness.
  • Page 28: Resin Exchange Capacity And Capacity Of The Unit

    Installer Manual Fleck 5800 - LXT - System sizing 4.2.3. Resin exchange capacity and capacity of the unit The resin exchange capacity and capacity of the unit are two different things that should not be confused. The resin exchange capacity is the amount of Ca and Mg that can be retained by 1 litre of resin, which will depend on the resin type and salt dosage, whereas the capacity of the unit is the...
  • Page 29 Installer Manual Fleck 5800 - LXT - System sizing Salt amount Corresponding resin exchange °f.m °dH.m [g/L capacity in [g/L ] as CaCO [per L [per L resin resin resin resin 58.5 5.85 3.27 62.7 6.27 66.9 6.69 3.74 3.97 75.3 7.53 4.21...
  • Page 30: Valve Configuration

    Installer Manual Fleck 5800 - LXT - System sizing 4.2.4. Valve configuration Knowing the volume of resin, tank size and specifications of the resin, it is possible to determine the required valve configuration. The resin specification will give the backwash velocity, as well as the brine draw and slow rinse velocity that must be respected in order to ensure a proper regeneration of the unit.
  • Page 31: Cycle Time Calculation

    Installer Manual Fleck 5800 - LXT - System sizing 4.2.5. Cycle time calculation From this point, the volume of resin, the tank size, the capacity of the softener and the valve configuration are determined. Next step is to calculate the regeneration cycle duration, which depends on the valve configuration and once again on the resin specifications.
  • Page 32 Installer Manual Fleck 5800 - LXT - System sizing To calculate the brine draw duration: Knowing the injector draw flow rate at the working pressure: with: brine draw brine draw : brine draw duration [min] brine draw : brine volume to be drawn [L], see Refill calculation brine page 33 : injection draw flow rate [L/min]...
  • Page 33: Salt Amount Definition

    Installer Manual Fleck 5800 - LXT - System sizing To calculate the refill duration: The refill flow rate is controlled by the refill controller (BLFC). The relation between the BLFC size, the tank size and the resin volume is given in the valve specifications. To calculate the refill duration: with: refill...
  • Page 34: 1650 Injector Flow Rates

    Installer Manual Fleck 5800 - LXT - System sizing 4.4. 1650 Injector flow rates The following tables and graphics represent the injectors flow rate as a function of the inlet pressure for the different injector sizes. INJECTOR 000 Total Rinse Draw Inlet pressure [bar] INJECTOR 00...
  • Page 35 Installer Manual Fleck 5800 - LXT - System sizing INJECTOR 0 Total Rinse Draw Inlet pressure [bar] INJECTOR 1 Total Rinse Draw Inlet pressure [bar] INJECTOR 2 Total Rinse Draw Inlet pressure [bar] Ref. MKT-IM-005 / C - 22.05.2018 35 / 88...
  • Page 36 Installer Manual Fleck 5800 - LXT - System sizing INJECTOR 3 Total Rinse Draw Inlet pressure [bar] INJECTOR 4 Total Rinse Draw Inlet pressure [bar] INJECTOR 5 Total Rinse Draw Inlet pressure [bar] 36 / 88 Ref. MKT-IM-005 / C - 22.05.2018...
  • Page 37: Installation

    Installer Manual Fleck 5800 - LXT - Installation Installation Mandatory It is strictly forbidden for not qualified personal, to accede to system’s internal parts to perform any kind of technical action. Be sure to disconnect the electrical power, close the water inlet and depressurize the system before opening the front cover to access internal parts.
  • Page 38: Water

    Installer Manual Fleck 5800 - LXT - Installation • follow State and local codes for water testing. Do not use water that is micro-biologically unsafe or of unknown quality; • when installing the water connection (bypass or manifold) first connect to the plumbing system. Allow heated parts to cool and cemented parts to set before installing any plastic parts.
  • Page 39: Integration Constraints

    Installer Manual Fleck 5800 - LXT - Installation • existing plumbing should be in a good shape and free from limescale. In case of doubt, it is preferable to replace it; • all plumbing must be completed according to local codes and installed without tension or bending stresses;...
  • Page 40: Top-Mounted Valve Installation

    Installer Manual Fleck 5800 - LXT - Installation 5.5.1. Top-mounted valve installation When pressurized, any composite tank will expand both vertically and circumferential. In order to compensate the vertical expansion, the piping connections to the valve must be flexible enough to avoid overstress on the valve and tank.
  • Page 41 • in any case, any failure caused by improper installation and/or piping connections may void the warranty of Pentair products; • in the same way, using lubricant* on the valve thread is not allowed and will void the warranty for the valve and tank.
  • Page 42: Block Diagram And Configuration Example

    Installer Manual Fleck 5800 - LXT - Installation 5.6. Block diagram and configuration example Block diagram Pressure gauge Main inlet User’s line Check valve to prevent water harm Filter cartridge By-pass Pressure regulator Meter Suggested options Mixing device Can be integrated in the Drain line valve Brine line...
  • Page 43: Regeneration Types

    Installer Manual Fleck 5800 - LXT - Installation 5.7. Regeneration types Softener metered delayed: The controller measures the water usage. The system regenerates at the pre-programmed time after the calculated system capacity is depleted. The controller calculates the system capacity by dividing the unit capacity by the feedwater hardness.
  • Page 44: By-Passing

    Installer Manual Fleck 5800 - LXT - Installation 5.9. By-passing A bypass valve system should be installed on all water conditioning systems. Bypass valves isolate the softener from the water system and allow unconditioned water to be used. Service or routine maintenance procedures may also require that the system is bypassed.
  • Page 45: Drain Line Connection

    Installer Manual Fleck 5800 - LXT - Installation 5.10. Drain line connection Note Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system. Caution The drain line plastic elbow must always be hand-tighten without using the elbow as a lever. Caution...
  • Page 46 Installer Manual Fleck 5800 - LXT - Installation  Note Waste connections or the drain outlet shall be designed and constructed to provide connection to the sanitary waste system through an air-gap of 2 pipe diameters or 50.8 mm (2"), whichever is larger. Caution...
  • Page 47: Overflow Line Connection

    Installer Manual Fleck 5800 - LXT - Installation 5.11. Overflow line connection In the event of a malfunction, power failure, etc, the brine tank overflow fitting will direct “overflow” to the drain instead of spilling on the floor. This fitting should be on the side of the cabinet or brine tank.
  • Page 48: Programming

    Installer Manual Fleck 5800 - LXT - Programming Programming Note If no button is pressed for 30 seconds in the programming mode the controller returns to Service mode. Note During programming, the controller continues to operate normally monitoring water usage and keeping all data up to date.
  • Page 49: Commands

    Installer Manual Fleck 5800 - LXT - Programming 6.2. Commands Press MODE to pass to the next programming option. Press and hold until the Time of Day icon appears. to adjust the values. Press and hold until the Programming icon disappears to save your programming. 6.3.
  • Page 50 Installer Manual Fleck 5800 - LXT - Programming 6.4.2.2 Setting the salt amount Set the salt amount in the system. Press MODE until display position point to the Salt Amount icon. Press and hold until the Programming icon appears. Set the salt amount with , 50 to 290 g/l (metric).
  • Page 51: Softener Time Clock Delayed Programming

    Installer Manual Fleck 5800 - LXT - Programming 6.4.3. Softener time clock delayed programming 6.4.3.1 Setting the regeneration time Set the regeneration time in the system. Press MODE until display position point to the Regeneration Time icon. Press and hold until the Programming icon appears.
  • Page 52: Filter Time Clock Programming

    Installer Manual Fleck 5800 - LXT - Programming 6.4.4. Filter time clock programming 6.4.5. Setting the tank capacity of filtration Note Setting the tank capacity of filtration must be done first. Anytime this parameter is changed, other parameters (salt dosage, water hardness,...) will be reset to default value. Set the tank capacity.
  • Page 53: Diagnostic

    Installer Manual Fleck 5800 - LXT - Programming 6.4.5.3 Setting the days between backwash Set the days between backwash. Press MODE until display position point to the Days Between Backwash icon. Press and hold until the Programming icon appears. Set the number of days between backwash with , 1 to 30.
  • Page 54 Installer Manual Fleck 5800 - LXT - Programming Diagnostic Description Notes code Days since last regeneration 0 - 30 Current flow rate l/min Current day of week 1 - 7 Total volume of water treated by the unit for the current day Total volume of water used since the last regeneration i.e.
  • Page 55: Commissioning

    Installer Manual Fleck 5800 - LXT - Commissioning Commissioning Note This chapter is available for standard regeneration types. Contact your supplier if the actual regeneration is not standard and if you need assistance. 7.1. Water filling, draining and waterproofness inspection 7.1.1.
  • Page 56: Sanitization

    Installer Manual Fleck 5800 - LXT - Commissioning 7.2. Sanitization 7.2.1. Disinfection of water softeners The materials of construction of the modern water softener will not support bacterial growth, nor will these materials contaminate a water supply. In addition, during normal use, a softener may become polluted with organic matter, or in some cases with bacteria from the water supply.
  • Page 57: Electro Chlorination

    Installer Manual Fleck 5800 - LXT - Commissioning Brine tank softeners Backwash the softener and add the required amount of hypochlorite to the well of the brine tank. The brine tank should have water in it to permit the chlorine solution to be carried into the softener. Proceed with the normal regeneration.
  • Page 58: Operation

    Installer Manual Fleck 5800 - LXT - Operation Operation 8.1. Display during operation Examples: • Valve in service with actual time of day: • Valve in service with volume remaining to next regeneration (in m 8.2. Display during regeneration During a regeneration the display shows the current cycle step and the time remaining for that cycle. The countdown for the time remaining starts only when the valve is in the cycle displayed.
  • Page 59: Manual Regeneration

    Installer Manual Fleck 5800 - LXT - Operation 8.5. Manual regeneration Mandatory The controller must be in service in order to enable this procedure. 8.5.1. Manual delayed regeneration Press once for delayed regeneration. → The regeneration starts on the scheduled time. See chapter 6.4.3. Softener time clock delayed programming, page 51.
  • Page 60: Maintenance

    Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper functioning of the complete system, and be documented in the Maintenance chapter in the User Guide document. Mandatory The maintenance must be done by a professional certified by Pentair, otherwise the warranty will void. 9.1. Recommendations 9.1.1.
  • Page 61: Controller Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.2. Controller replacement Operation Press the cover clips (2) on each side and open the cover (1). Press the board clips (3) and release the controller (4). Disconnect the old controller. Connect the new controller, see 5.8. Electrical connections, page 43. Reverse above procedure steps to rebuild.
  • Page 62: Controller Motor Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.3. Controller motor replacement Operation Remove the controller, see 9.2.2. Controller replacement, page 61. Disconnect the optical sensor (3). Disconnect the motor. Open the motor clips (1) and pull out the old motor (2). Change the motor (2).
  • Page 63: Power Head Disassembly/Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.4. Power head disassembly/replacement Operation Remove the controller, see 9.2.2. Controller replacement, page 61. Using a 6 mm wrench or flat screwdriver, unscrew (2). Using a 8 mm wrench or flat screwdriver, unscrew (1). Separate the gearing system (3) from the valve body (4).
  • Page 64: Piston And/Or Brine Valve Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.5. Piston and/or brine valve replacement Operation Remove the gearing system, see “Power head disassembly/replacement”, page 63. Remove the screws (1). Remove the piston and the top plate (2) by pulling the top plate on the points indicated by arrows.
  • Page 65: Seals And Spacers Cartridge Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.6. Seals and spacers cartridge replacement Operation Remove the piston, see “Piston and/or brine valve replacement”, page 64. Remove the seals and spacers cartridge (1). Change the seals and spacers cartridge (1). ®...
  • Page 66: Injector Cleaning

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.7. Injector cleaning Operation Remove the screws (4). Remove the cap injector (3). Remove the seal (4) taking note of its position. Caution Depending of configuration, the position of the seal can be different as shown. The mid part of the seal should be aligned with the position of the injector.
  • Page 67: Blfc Cleaning

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.8. BLFC cleaning Operation Remove the BLFC holder (1). Using pliers, remove the grid (4) from BLFC holder (1). Remove the BLFC (3) from the grid (4). Clean or change the BLFC (3) and the seal (2). ®...
  • Page 68: Optical Sensor Replacement

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.9. Optical sensor replacement Operation Remove the controller, see 9.2.2. Controller replacement, page 61. Disconnect the wire from the motor to the optical sensor (4). Release the optical sensor support (1) by pushing it back and up as shown. Release the optical sensor (3) from its support (1) by pressing the clips (2).
  • Page 69: Encoding Wheel Cleaning

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.10. Encoding wheel cleaning Operation Remove the controller, see 9.2.2. Controller replacement, page 61. With a small brush, clean the encoding wheel (1). Reverse above procedure steps to rebuild. Ref. MKT-IM-005 / C - 22.05.2018 69 / 88...
  • Page 70: Valve On Tank Assembly

    Installer Manual Fleck 5800 - LXT - Maintenance 9.2.11. Valve on tank assembly Operation Lubricate the seals with approved silicone grease. Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded. Rotate the valve (1) clockwise and freely, without using force until it comes to a stop. Note...
  • Page 71: Troubleshooting

    Installer Manual Fleck 5800 - LXT - Troubleshooting Troubleshooting Problem Cause Solution Cord plugged into intermittent or Connect to constant power source. switched off power source. Water softener Disconnected/faulty meter cable. Reconnect/replace cable. fails to regenerate Defective power cord. Replace cord. automatically.
  • Page 72 Installer Manual Fleck 5800 - LXT - Troubleshooting Problem Cause Solution Check flow to drain. Clean flow Plugged Drain Line. control. Excessive water in Dirty or damaged brine valve. Clean or replace brine valve. brine tank and/or Plugged injector. Clean injector and replace screen. salty water to Increase pressure to allow injector to service.
  • Page 73: Error Detection

    Installer Manual Fleck 5800 - LXT - Troubleshooting 10.1. Error detection Errors codes appear on the service display. Note It can take up to 1 minute before an error can be detected and displayed. 10.2. Error types and causes 10.2.1. Motor stall/cam sense error Note...
  • Page 74: Regeneration Failure

    Installer Manual Fleck 5800 - LXT - Troubleshooting 10.2.3. Regeneration failure Note The system has not regenerated for more than 30 days. Perform a manual regeneration to reset the error code. If the system is metered, verify that it is measuring flow by running service water and watching for the flow indicator on the display.
  • Page 75: Spare Parts

    Installer Manual Fleck 5800 - LXT - Spare parts Spare parts 11.1. Power head parts list Assembly Min. order Item Part number Description quantity quantity BR61836 Panel gear assembly, downflow/upflow BR61833-01 Controller assembly Storm TC BR61833-02 Controller assembly Storm Eco BR61833-03 Controller assembly Storm TC UF BR61833-04...
  • Page 76: Valve Parts List

    Installer Manual Fleck 5800 - LXT - Spare parts 11.2. Valve parts list Assembly Min. order Item Part number Description quantity quantity 18261SP Screw, hex washer head, #10-24 x 0.81" BR61837 Piston and seal kit assembly, downflow 5800 BR61838 Piston and seal kit assembly, upflow 5800 60032 Brine valve 4600/5600 13333...
  • Page 77 Installer Manual Fleck 5800 - LXT - Spare parts Assembly Min. order Item Part number Description quantity quantity 18332-0.50 BLFC, 0.50_gpm, 5000/5600/9000 18332-1 BLFC, 1.00_gpm, 5000/5600/9000 18272-000SP Injector assembly, 1610, #000, brown 18272-00SP Injector assembly, 1610, #00, violet 18272-0SP Injector assembly, 1610, #0, red 18272-1SP Injector assembly, 1610, #1, white 18272-2SP...
  • Page 78: Safety Brine Valve Parts List

    Installer Manual Fleck 5800 - LXT - Spare parts Assembly Min. order Item Part number Description quantity quantity 24078-7 DFLC, plastic, 7.0 gpm & hose barb bent 26147-8 DFLC, 1" assembly 8 gpm 26147-9 DFLC, 1" assembly 9 gpm 26147-10 DFLC, 1"...
  • Page 79: Safety Brine Valves List

    Installer Manual Fleck 5800 - LXT - Spare parts Assembly Min. order Item Part number Description quantity quantity 19649 Flow disperser PWG19652-01 Poppet assembly, SBV, with o-ring 18312SP Retainer, drain PWG19803 Safety brine valve arm assembly 19645 Body, safety brine valve, 2310 19805SP Plastic SBV 2310 Nut 19804...
  • Page 80: Bypass Valve Assembly List

    Installer Manual Fleck 5800 - LXT - Spare parts 11.5. Bypass valve assembly list 11.5.1. Plastic bypass (no yoke) 80 / 88 Ref. MKT-IM-005 / C - 22.05.2018...
  • Page 81 Installer Manual Fleck 5800 - LXT - Spare parts Assembly Min. order Item Part number Description quantity quantity BU26054 Bypass plastic 13314SP Screw, slot ind, hex, 8-18 x 0.60" 13255SP Clip mounting 13305-01SP O-ring 18706-10 Yoke, 1", BSP, male, plastic 18706-12 Yoke, ¾", BSP, male, plastic 24689...
  • Page 82: 1" Bsp Female Stainless Steel Bypass

    Installer Manual Fleck 5800 - LXT - Spare parts 11.5.2. 1" BSP female stainless steel bypass 82 / 88 Ref. MKT-IM-005 / C - 22.05.2018...
  • Page 83 Installer Manual Fleck 5800 - LXT - Spare parts Assembly Min. order Item Part number Description quantity quantity BU28502 Bypass Stainless Steel 1" BSP 13386SP Screw Hex Hd Mach 1/4-20 X 1 Or Slot Hex 24419-10SP Bypass handle red 15727 Screw, Hex washer head 10-24 x 0.5"...
  • Page 84: Plastic Turbine Meter Assembly

    Installer Manual Fleck 5800 - LXT - Spare parts 11.6. Plastic turbine meter assembly Assembly Min. order Item Part number Description quantity quantity 60626-01 Meter turbine assembly ¾" SXT BR19791-01 Meter cable turbine assembly 19797 Meter turbine assembly 5800 19569SP Clip 13314SP Screw...
  • Page 85: Ce Compliance Part List

    Installer Manual Fleck 5800 - LXT - Spare parts 11.7. CE compliance part list Assembly Min. order Item Part number Description quantity quantity 18280SP Collector top 1” x 0.011 grey bayonet 21511SP Hose barb 90° ½” x ½”, black or grey Ref.
  • Page 86: Disposal

    This will help to reduce the impact on the environment, health, safety and help to promote recycling. Pentair does not collect used product for recycling. Contact your local recycling center for more information.
  • Page 87 Installer Manual Fleck 5800 - LXT - Disposal PAGE INTENTIONALLY LEFT BLANK Ref. MKT-IM-005 / C - 22.05.2018 87 / 88...
  • Page 88 www.pentairaquaeurope.com...

Table of Contents