Pentair FLECK 5800 SXT Service Manual

Pentair FLECK 5800 SXT Service Manual

Downflow/upflow residential water filtration
Hide thumbs Also See for FLECK 5800 SXT:

Advertisement

FLECK 5800 SXT DOWNFLOW/UPFLOW
SERVICE MANUAL
waterpurification.pentair.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5800 SXT

  • Page 1 FLECK 5800 SXT DOWNFLOW/UPFLOW SERVICE MANUAL waterpurification.pentair.com...
  • Page 2: Table Of Contents

    This product contains chemicals known to the • Correct and constant voltage must be supplied to WARNING: the controller to maintain proper function. State of California to cause cancer or birth defects or other reproductive harm. 2 • FLECK 5800 SXT Upflow/Downflow...
  • Page 3: Installation

    When power is 1. Place the softener tank where you want to install the unit. restored, the time setting must then be re-entered. Make sure the unit is level and on a firm base. FLECK 5800 SXT Upflow/Downflow • 3...
  • Page 4: Start-Up Instructions

    1. Press the Extra Cycle button. The service icon will flash to indicate that a regeneration is queued. 2. To cancel a queued regeneration, press the Extra Cycle button. Regenerating Immediately Press and hold the Extra Cycle button for five seconds. 4 • FLECK 5800 SXT Upflow/Downflow...
  • Page 5: User Programming

    7. Press the Extra Cycle button to end User Programming. Figure 5 3. Press the Extra Cycle button. Use this display to adjust the Regeneration Time. This option setting is identified by "RT" in the upper left corner of the screen. Figure 6 FLECK 5800 SXT Upflow/Downflow • 5...
  • Page 6: Control Operation

    The control only enters the Program Mode with the valve in service. While in the Program Mode, the control continues to operate normally monitoring water usage and keeping all displays up to date. Control programming is stored in memory permanently. 6 • FLECK 5800 SXT Upflow/Downflow...
  • Page 7: Master Programming Mode Chart

    Flow Based (Fb), volume interval (VO), time on (TO) NOTE: Some items may not be shown depending on control configuration. The control will discard any changes and exit Master Programming Mode if any button is not pressed for five minutes. FLECK 5800 SXT Upflow/Downflow • 7...
  • Page 8: Master Programming Mode

    Other Upflow Master Reset Hold the Extra Cycle button while powering up the unit. This resets all of the parameters in the unit. Check and verify the choices selected in Master Programming Mode. Figure 12 8 • FLECK 5800 SXT Upflow/Downflow...
  • Page 9 Use the Up and Down buttons to adjust the value as Up and Down buttons to adjust the value as needed. needed. Figure 15 Range: 1-199 grains (degrees) Figure 18 Range: 0-half of the calculated system capacity FLECK 5800 SXT Upflow/Downflow • 9...
  • Page 10 Figure 23 upper left corner of the screen. The abbreviations used are listed below. 10 • FLECK 5800 SXT Upflow/Downflow...
  • Page 11 K Range: 0.1 to 999.9 pulses per gallon. TO Range: 1 to 7200 (minutes) 19. End of Master Programming Mode Press the Extra Cycle button to save all settings and exit Master Programming Mode. FLECK 5800 SXT Upflow/Downflow • 11...
  • Page 12: Viewing Diagnostic Data

    Rate since the last regeneration cycle. This option setting is identified by "PF" in the upper left corner of the screen. Figure 38 9. Press the Extra Cycle button to end Diagnostic Programming Mode. Figure 34 12 • FLECK 5800 SXT Upflow/Downflow...
  • Page 13: System Disinfection

    A. Backwash the softener and add the required amount of hypochlorite to the well of the salt tank. The salt tank should have water in it to permit the chlorine solution to be carried into the softener. B. Proceed with the normal recharge. FLECK 5800 SXT Upflow/Downflow • 13...
  • Page 14: Troubleshooting

    If error continues, call technical support. ---4 Fail Safe Error Valve has failed to find position in Unplug the unit and plug it back in. If error continues, call technical one minute. support. 14 • FLECK 5800 SXT Upflow/Downflow...
  • Page 15: Powerhead Assembly

    4....1 ..61835 ....Motor Assembly 5....1 ..61882 ....Cover Assembly, Environmental 6....1 ..44161 ....Transformer, 12V UL 7....1 ..44162 ....Transformer, Intl, 12V UL 8....1 ..43715 ....Cover, Lower, 5800 Series BR61882 Rev B FLECK 5800 SXT Upflow/Downflow • 15...
  • Page 16: 5800 Control Valve Assembly

    Excessive side load on piston rod may cause premature CAUTION damage. If seal/spacer stack is stuck in valve bore during ..60705-08 ....DLFC, Plastic, 0.80 gpm disassembly, rotate stack prior to removal... 60705-10 ....DLFC, Plastic, 1.0 gpm 16 • FLECK 5800 SXT Upflow/Downflow...
  • Page 17: Turbine Meter Assembly - P/N 60626

    8....4 ..12473 ....Screw, Hex Wsh, 10-24 x 5/8 9....4 ..13255 ....Clip, Mounting 10 ....4 ..13314 ....Screw, Slot Ind Hex, 8-18 x 0.60 11 ....4 ..13305 ....O-ring, -119 12 ....1 ..14613 ....Flow Straightener FLECK 5800 SXT Upflow/Downflow • 17...
  • Page 18: Bypass Valve Assembly (Metal)

    10 ....1 ..60040SS .....Bypass Valve, 5600, 3/4" NPT 2 ..19228-01 ....Adapter Assy, Coupling, Black Grip Lever, SS w/O-rings ..60041SS .....Bypass Valve, 5600, 1" NPT Black Grip Lever, Stainless Steel Not Shown: 2 ..19228-01 ....Adapter Assy, Coupling, w/O-rings 18 • FLECK 5800 SXT Upflow/Downflow...
  • Page 19: Safety Brine Valve

    ..60002-34 ....Air Check, #500, 34" Long ..60002-36 ....Air Check, #500, 36" Long ..60002-48 ....Air Check, #500, 48" Long ..60002-26.25 ..Air Check, #500, 26.25" Long ..60002-33.25 ..Air Check, #500, 33.25" Long FLECK 5800 SXT Upflow/Downflow • 19...
  • Page 20: Water Conditioner Flow Diagrams

    WATER CONDITIONER FLOW DIAGRAMS Upflow 1. Service Position 4. Rapid Rinse Position 2. Brine/Slow Rinse Position 5. Brine Tank Refill Position 3. Backwash Position 20 • FLECK 5800 SXT Upflow/Downflow...
  • Page 21 WATER CONDITIONER FLOW DIAGRAMS continued Downflow 1. Service Position 4. Rapid Rinse Position 2. Backwash Position 5. Brine Tank Refill Position 3. Brine/Slow Rinse Position FLECK 5800 SXT Upflow/Downflow • 21...
  • Page 22: Dimensional Drawings

    DIMENSIONAL DRAWINGS 12.7 53.8 111.3 2.12 4.38 91.4 3.60 182.9 7.20 BR61500-5800LNE Rev A 22 • FLECK 5800 SXT Upflow/Downflow...
  • Page 23: Injector Flow Data

    INJECTOR FLOW DATA TR18755 Rev B FLECK 5800 SXT Upflow/Downflow • 23...
  • Page 24 For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com/brands. § Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners.