4.

System sizing

4.1.

Recommendations

4.1.1. Injector/DLFC/BLFC-Valve configuration

Tank
Valve
diameter
type
[in]
8
9
10
12
5810/
13
1650
14
16
21
24
Note
For upflow configuration, it is highly recommended to use the injector cap 61923-20,
equipped with a pressure regulator.
4.2.

Sizing a softener (single unit)

4.2.1. Parameters to be considered

Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
28 / 124
Resin
volume
L
DF
Color
9 - 21
00
Violet
22 - 28
0
Red
29 - 42
1
White
43 - 56
2
Blue
57 - 70
3
Yellow
71- 85
86 - 113
4
Green
114 - 198
5
Grey
199 - 283
Injector
UF
Color
000
Brown
00
Violet
0
Red
1
White
2
Blue
3
Yellow
4
Green
Ref. MKT-IM-018 / C - 08.06.2018
DLFC
BLFC
[gpm]
DF [gpm] UF [gpm]
1.5
2.0
0.25
2.4
3.5
4.0
0.50
5.0
7.0
10.0
1.00
15.0
0.25
0.50
1.00