Installer Manual Fleck 5810 - XTR - System sizing
4.
System sizing
4.1.
Recommendations
4.1.1. Injector/DLFC/BLFC-Valve configuration
Tank
Valve
diameter
type
[in]
8
9
10
12
5810/
13
1650
14
16
21
24
Note
For upflow configuration, it is highly recommended to use the injector cap 61923-20,
equipped with a pressure regulator.
4.2.
Sizing a softener (single unit)
4.2.1. Parameters to be considered
Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
28 / 124
Resin
volume
L
DF
Color
9 - 21
00
Violet
22 - 28
0
Red
29 - 42
1
White
43 - 56
2
Blue
57 - 70
3
Yellow
71- 85
86 - 113
4
Green
114 - 198
5
Grey
199 - 283
Injector
UF
Color
000
Brown
00
Violet
0
Red
1
White
2
Blue
3
Yellow
4
Green
Ref. MKT-IM-018 / C - 08.06.2018
DLFC
BLFC
[gpm]
DF [gpm] UF [gpm]
1.5
2.0
0.25
2.4
3.5
4.0
0.50
5.0
7.0
10.0
1.00
15.0
0.25
0.50
1.00