Chapter 10: Troubleshooting
5 If there is a FUNCTION error and an E appears on the display, press the
6 If an FUNCTION error continues to appear, turn the Mode key to the
7 As a last resort, follow the directions for a Full System Clear. See Full

EJ -FULL Error

This prompt means the Electronic Journal is full. The Electronic Journal
can hold up to 5,460 lines of transactions. When the memory gets close to
full, you see a bar in the lower left of the display and you hear a long
beep.
When the memory is completely full, no more transactions can be saved
and you see a message in the display that says E.J. -Full. If you are in
the middle of a transaction, press the Clear key to clear the error message,
and continue with the transaction. No additional transaction details or
information can be stored in the Electronic Journal memory after you
clear this error message.
To fix this, you need to print the Z report to clear the memory. It is very
strongly recommended that immediately after the current transaction is
finished, that you either print the Electronic Journal record in Z-Mode or
manually reset the Electronic Journal record memory.
Before you start, make sure there is a lot of paper on the receipt paper roll
so the Z Electronic Journal reports can print completely.
Note
You cannot download the Electronic Journal record to the PC using the
serial connection.
1 At the end of the day, turn the Mode key to the Z position.
2 Run the normal end-of-day reports, including a standard Z Report by
3 Using the round Number keys area, press 96 to print the Electronic
4 Press the Amount Tend Total key.
100
Clear key.
last position (PRG, REG, X or Z) you were in before the error appeared.
If the last position you were in was REG, turn the Mode key to the REG
position and press the Clear key, then press the Amount Tend Total,
Check, or Charge key to complete a pending sale.
If your last position was PRG, turn the Mode key to the PRG position
and press the Clear key.
System Clear on page 103.
pressing the Amount Tend Total key while in Z Mode.
Journal record.