Error Code Corresponding List Table - Royal 220DX Operation Manual

Table of Contents

Advertisement

15 ERROR
LIST TABLE
Error
Code
E001
-------
E002
-------
E003
-------
E004
-------
E005
-------
E006
-------
E007
-------
E008
-------
E009
-------
E010
-------
E011
-------
E012
-------
E013
-------
E014
-------
E015
-------
E016
-------
E017
-------
E018
-------
E019
-------
E020
-------
E021
-------
E022
-------
E023
-------
E024
-------
E025
-------
E026
-------
E027
-------
E028
-------
E029
-------
CODE
Error Description
The input digit is too big or too small
The input digits format illegal
Press the illegal key
The input digits length is too long
Not allow pressed Decimal Point key in this case
The Decimal Point key has pressed already
The dept shift key is not allowed by the system flag
This key code nonexistent or UN-programmable
This PLU group is full
Only the Welcome& Bottom messages description support the
Decimal Point key input.
The description input all is blank (Except Welcome& Bottom
messages description)
The corresponding reports data is not empty
The payment is not end
The sale no end
No new sale
Zero payment is not allowed
Zero transaction is not allowed
The VOID operation input digit is too big
Item Refund operation, the input digit is larger than the transaction
price
The transaction is full (Must do the tender)
Transaction amount reaches maximum
The transaction's quantity is reach to the max
Refund or Percent operation, the corresponding flag not allow this
operation
(HALO) Transaction amount too big
Nonexistent department
The multiplication operations max quantity is 9999.999
The Percent operations rate can't be 0
This operation is not allowed in Z mode
Doing the individual report
CORRESPONDING
69