Epson Stylus Photo R2000s Series Service Manual page 90

Table of Contents

Advertisement

EPSON Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series
3.
Pull off the connector of the electrode cable from its terminal on the High Voltage
Module Board with long-nose pliers or the like.
4.
Disconnect the High Voltage Module cable from connector CN1 on the High
Voltage Module Board.
5.
Remove the
C.B.P. M3 x 8
screw and remove the High Voltage Module Board.
4) C.B.P. M3x8
High Voltage
Module cable
Hook
Figure 4-38. Removing the High Voltage Module Board (2)
Wind the High Voltage Module cable on the hook one time as
shown in
Figure
4-38.
Route the electrode cable as shown in the figure below.
Wind it on
the hook.
Figure 4-39. Routing the Electrode Cable
Disassembly And Assembly
Electrode cable terminal
CN1
Electrode cable
55±2mm
Acetate Tape
Removing the Boards
A D J U S T M E N T
After replacing the High Voltage Module, always make the required
R E Q U I R E D
adjustments referring to the following.
• "Chapter 5
Adjustment
Revision I
(p.139)"
90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents