With its conductor connection portion up, set the Adjustment Gauge in the
specified position (on the left side of the Front Paper Guide).
Setting Position
Rear direction: Match the rear end of the Gauge with the Driven Roller Shaft
of the Upper Paper Guide.
Left direction: Release the left end of the Gauge from the Tab on the Front
Paper Guide in
Conductor Connection Point
Tab
Figure 5-6. Setting the Adjustment Gauge
7.
Move the Carriage Unit onto the Adjustment Gauge.
Moving position
Match the left end of the Gauge with the left end of the Carriage Unit.
Figure 5-7. Moving the Carriage Unit
Adjustment
Figure
5-6.
Setting Position
Setting Position
8.
To set the PG position to the "--" position, turn the PG Cam on the right end of the
Carriage Shaft clockwise so that the point marked "--" faces down.
Figure 5-8. Markings of the PG Cam
PG Standard Value
A D J U S T M E N T
R E Q U I R E D
PG – – (Minus Minus) :1.05mm~1.25mm
PG – (Minus)
Adjustment Resolution
Adjustment
Revision I
PG Cam
:1.2mm~1.4mm
:
0.06mm