Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series
18. Perform color measurement according to the instruction on the window. Press
and hold the button on the calibrator and wait for one to two seconds, and then
keep holding it and slide the calibrator at a steady speed in the measuring
direction from the measurement start point shown in
i1Pro:
Slide the calibrator on the calibration patches from left to right in
approximately five seconds.
i1Pro2: Slide the calibrator on the calibration patches from left to right in
approximately five seconds, and let go of the button once. And then,
press and hold the button on the calibrator again, and then keep
holding it and slide the calibrator on the calibration patches from
right to left in approximately five seconds.
  When the color measurement is successfully complete, " " appears, and
then perform the color measurement on the next row.
Table 9-11. Limitations of the calibrator
i1Pro
Upper left on the color chart
Measurement
start point
In the direction of the arrow in
Figure 9-16
only. An error occurs
if scanned in the reverse
Measuring
direction.
direction
Once
Times of
measurements
per row
Perform the measurement of the
When the
failed row. Cannot go on to the
measurement
next row until the measurement
fails
is successfully complete.
SC-P400 Series
.
Figure 9-16
i1Pro2
Upper left on the color chart
Outward (tungsten light): In
the direction of the arrow in
Figure 9-16
only.
Inward (UV light): In the
reverse direction from the
outward scanning
Two times (one cycle)
Perform the measurement of the
failed row. Cannot go on to the
next row until the measurement
is successfully complete.
Adjustment
 During color measurement, do not allow the calibrator
C A U T I O N
to rub against unmeasured patches on the chart.
 Prevent the ruler and calibrator from coming off the
chart sheet during color measurement. Doing so will
cause incorrect color measurement.
 Do not press the calibrator to the chart too strongly,
otherwise the patch may be damaged.
 If "!" appears repeatedly and the measurement fails
continuously, the measured color value may be far out of
the standard range. In that case, end the measurement
and go to the troubleshooting below.
Revision I
227