Ricoh R-C4 Service Manual page 429

Table of Contents

Advertisement

21 July 2006
CC Auto Call
The CC auto call will be automatically generated when "0: Previous Mode" is
selected with SP5-508-4 (default is "1"). There are three types of CC auto calls as
follows.
CC Code
When a paper jam is detected five times consecutively, CC101 is
CC 101
automatically generated.
When a paper jam condition is not reset for 15 minutes, CC201 is
CC 201
automatically generated.
When a cover is left open for 15 minutes, CC202 is automatically
CC 202
generated.
Alarm Calls
There are four types of Alarm Calls as follows:
Type
When the PM counter reaches 120,000, a PM Alarm Call is automatically
PM
reported to the Concorde system.
An alarm call is generated after the specified total number of originals goes
Original Count
through the ARDF.
When the SC alarm counter reaches 5, an SC Alarm Call is automatically
SC
generated. The SC alarm counter counts the number of SCs and it
decreases when an SC does not occur for a specified number of copies.
When Jam alarm counter reaches 10, a Jam Alarm Call is automatically
generated. The Jam Alarm counter counts the number of paper jams and it
Jam
decreases when a paper jam does not occur for a specified number of
copies.
CHECKING ITEMS USING RSS
Definition
Definition
APPENDIX-5