Installer manual Fleck 2750 NXT/NXT2 - Programming
1. Adjust the cycle time with
2. Press
to validate the selection and advance to the next
parameter.
3. Repeat for each cycle.
6.1.5.19 Auxiliary relay/Chemical pump
Mandatory
The system can be set only with auxiliary relay or chemical pump !
Auxiliary relay
Set the relay output during regeneration.
Options:
• Disabled (default);
• Enabled.
Info
This parameter has two steps of settings.
The first one activates the output, and the second one deactivates the output.
The time 00:00:00 correspond to the beginning of regeneration time.
78 / 170
,
and
.
1. Backwash: 10 min
(default).
2. Draw/Slow rinse:
1 h 00 min (default).
3. Fast rinse: 10 min
(default).
4. Refill: 12 min (default).
5. Pause: not used (default).