9.4.2.2
Valve with NXT2 controller
Caution - material
Risk of damage due to AC motor use !
Use only DC motor with NXT2 controller.
1. Using a flat screwdriver, unscrew (1) and open the cover (2).
2. Open the controller (3).
3. Disconnect the motor (5) and the microswitches (6).
4. Using pliers, remove the connecting pin (4).
5. Using a 19 mm wrench, unscrew the brine valve nut (8).
6. Using a flat screwdriver or an 11 mm wrench, unscrew (7) and remove the motor (5).
7. Change the motor (5) and reverse above procedure steps to rebuild
Ref. MKT-IM-026 / C - 15.12.2020
Installer manual Fleck 2750 NXT/NXT2 - Maintenance
DC motor
139 / 170