Buell P3 2003 Service Manual page 348

Table of Contents

Advertisement

HOME
Is Bank Angle Sensor Connected?
YES
Disconnect Connector [134].
Measure Voltage On [134B] Between Socket A, LT GN/GY And Socket B, BK
3.0-3.5 VDC
See Next Page
Bank Angle Sensor
Connector [134]
NO
Reconnect.
11-13 VDC
Disconnect Connector [10]. Check Continuity Between Socket A, LT GN/GY
Repair Short On
On Connector [134B] And Socket 5, LT GN/GY On Connector [10B].
LT GN/GY Wire.
5007
Check Continuity To Ground On LT GN/GY Wire, Socket A,
8261
Figure 7-7. Continuous or No Spark At Spark Plug
*
To avoid damage to terminals, remove
Bank Angle Sensor before disconnecting
connector [134]. Use Harness Connector
Adapter Kit HD-41404,Gray male probe
0 VDC
Continuity Present?
YES
Check Continuity To Ground On TN/Y Wire, Socket B,
Connector [134B].
Is Continuity Present?
YES
Connector [134B] Or [10B].
Is Continuity Present?
YES
Repair Short To Ground On LT
GN/GY Wire.
5007
and patch cord
NO
Repair Open In
LT GN/GY Wire.
5007
NO
Check Starter
Interlock.
5007
NO
Inspect Module Harness For Damage.
Repair If Necessary.
If Harness Is Not Damaged, Replace
Ignition Module.
5009
2003 Buell P3: Electrical
7-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

99492-03y

Table of Contents