Removal Of Electrical Box - Daikin H Series Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for H Series:
Table of Contents

Advertisement

Indoor Unit
1.3

Removal of Electrical Box

Procedure
Step
1. Layout of the parts
2. Remove the drip proof
plate.
1
Remove the screw.
2
Remove the drip proof
plate from the indoor
heat exchanger.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Drip proof plate
Preparation
 Remove the front grille
according to the "Removal of
Front Grille."
1 2
3
(R9493)
3
1 2
(R9494)
 When reassembling, fit the hook
to the indoor heat exchanger.
(R9496)
SiUS04-924_A
Points
(R9495)
127

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents