Outdoor Unit
1.2
Removal of the Electrical Box
Procedure
Step
1. Disconnect the
connecting wires
Loosen the 2 grounding
1
screws.
Loosen the 2 screws to
remove the wiring
fixture.
Then loosen the all
screws for the
connectors to
disconnect the power
supply cable and the
connecting wires.
2. Remove the electrical box
1
Detach the outdoor air
thermistor from the
holder.
Lift up the guard net to
2
remove.
258
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Room A
Wiring
4
4
P
fixture
Outdoor air thermistor
Guard net
Fasten the wires with screws
on the terminal board.
The terminal board is united
Room B
resin formation.
Power supply
Grounding
screws
(R7573)
(R7208)
(R7209)
SiBE12-712C
Points