Main Functions
1.8

NIGHT SET Mode

Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in the
case of heating. This prevents excessive cooling in summer and excessive heating in winter to
ensure comfortable sleeping conditions, and also conserves electricity.
<Cooling>
<Heating>
Function and Control
Target temperature
TIMER operation
NIGHT SET Mode ON
Target temperature
TIMER operation
NIGHT SET Mode ON
0.5˚C (0.9˚F)
1 hour
+0.5˚C (+0.9˚F)
temperature shift
1 hour later
SiUS04-924_A
Operation stops
at the set hours
2˚C (3.6˚F)
(R14454)
(R14453)